Laserfiche WebLink
' 28 May 2003 <br /> AGE-NC Project No 95-0173 <br />' Page 5 of 8 <br /> 33,000 µg/1 (toluene, AW-2A) The maximum benzene concentration was detected from sample <br /> AW-2A at a concentration of 6,800 pg/1 <br />' MTBE was detected in a water sample collected from MW-5 at a concentration of 0 99 pg/l, <br /> 1,2-DCA was detected in water samples collected from MW-5 and AW-IB at concentrations of <br /> 0 95 µg/1 and 5 µg/l,respectively No other fuel components were detected in the samples analyzed <br /> Previous and current analytical results of ground water monitoring well samples are summarized in <br /> Tables 3 and 4,respectively The laboratory reports (CAL reference nos 5354 and 5359)and chain- <br /> of-custody forms are presented in Appendix C <br /> 43 RESULTS OF SOIL VAPOR EXTRACTION <br /> Between 26 September 2002 and 17 December 2002, the SVE and IAS remediation systems were <br /> operational for approximately 2,102 hours(Table 7) During the operational period, SVE inlet flow <br /> rates were calculated to be approximately 98 cubic feet per minute, differential pressures were <br /> observed at approximately 3 2 inches of water, and induced vacuum between 22 and 29 inches of <br /> water Utilizing a photo ionization meter (PID), hydrocarbon concentrations were measured at <br /> concentrations as high as 2,000 parts per million (ppm) at regular intervals at the SVE inlet Field <br /> measurements are summarized in Table 6 <br /> r <br /> 4 4 ANALYTICAL RESULTS OF VAPOR EXTRACTION AIR FLOW SAMPLES <br /> Influent and effluent SVE air flow samples were collected on 27 September, 24 October, <br /> 12 November and 17 December 2002 TPH-g was detected in all four influent SVE air flow samples <br /> at concentrations between 530 µg/1 and 3,400 µg/1 TPH-g was detected in the September, October <br /> and November 2002 effluent air flow samples at concentrations between 61 µg/1 and 210 µg/1 <br /> Various BTEX constituents were detected in all four influent SVE air flow samples at concentrations <br /> as high as 99 µg/l (xylenes, 24 October 2002), the maximum benzene concentration was detected <br /> in the November 2002 influent sample at a concentration of 9 6 µg/l Various benzene, toluene and <br /> xylene constituents were detected in all four effluent SVE air flow samples at concentrations as high <br /> as 4 4 µg/1 xylene <br /> Analytical results of SVE air flow samples are summarized in Table 5 The laboratory reports(Castle <br /> Analytical Laboratory I D Nos 5178, 5230 and 5334) and chain-of-custody forms are presented in <br /> Appendix D A plot of laboratory analysis of SVE influent TPH-g air flow concentrations versus <br /> time is included with Appendix E <br /> • <br /> Advanced Geo Environmental,Inc <br /> I <br />