FACILITY_NAME
UP TRACY RAIL YARD
STREET_NUMBER
720
Direction
E
STREET_NAME
SIXTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
25001014
CURRENT_STATUS
01
SITE_LOCATION
720 E SIXTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
515
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Table 1 Historical Product Measurement and Thickness <br /> Union Pacific Railroad Company <br /> Former Tracy Maintenance Facility <br /> Tracy,California <br /> Depth to Product Product <br /> Well Date Product Depth to Water Thickness Volume <br /> identification Measured (feet btc) (feet btc) (inches) (gal) Comments <br /> MW-06A 3/03/95 9.57 11.70 25.56 1.39 Measurement of free product layer. <br /> MW-06A 3/16/95 9.00 10.40 16.80 0.91 Product removed by bailer. <br /> MW-06A 4/06/95 9.62 11.86 26.88 1.46 Product removed by bailer. <br /> Approximately 6 gallons of product have been <br /> removed since first installation of the skimmer in <br /> MW-06A 5/15/95 1992. <br /> Approximately 110 gallons of product/water have <br /> MW-06A 6/19/95 been removed since 15 May 1995. <br /> Approximately 0.5 gallon of product has been <br /> MW-06A 11/28/95 10.20 10.30 1.20 0.07 removed since reinstallation of pump. <br /> MW-06A 2/19/96 8.70 8.71 0.12 0.01 Power off.Call for repair. <br /> Measurement of product layer. Remove product <br /> MW-06A 5/10/96 9.23 9.25 0.24 0.01 skimmer.Install two bilge bags. <br /> MW-06A 5/13/96 9.48 9.49 0.12 0.01 Measure product layer. Reinstall two bilge bags. <br /> No measurable product. Calculated weight of diesel <br /> MW-06A 7/15/96 NA 9.80 sheen 0.000 removed was 0.35 lb. <br /> MW-06A 7/22/96 - - - - Replace bilge bags with one bilge bag. <br /> MW-06A 11/14/96 8.84 8.88 0.48 0.03 Measure product layer. Install a fresh bilge bag. <br /> MW-06A 2/11/97 NA 8.14 sheen 0.000 No measurable product;sheen only. <br /> MW-06A 2/20/97 - - - - Replace bilge bag- <br /> MW-06A 5/22/97 NA 7.91 sheen 0.000 No measurable product. Replace bilge bag. <br /> MW-06A 7/28/97 8.41 8.42 0.12 0.01 Measure product layer. Replace bilge bag. <br /> MW-06A 10/31/97 9.48 9.52 0.48 0.03 Measure product layer. Replace bilge bag. <br /> MW-06A 2/12/98 7.78 7.80 0.24 0.01 Measure product layer. Replace bilge bag. <br /> MW-06A 5/11/98 7.68 7.68 0.00 0.00 Meter barely read product. Replace bilge bag. <br /> MW-06A 7/27/98 8.25 8.26 0.12 0.01 Measure product layer. Replace bilge bag. <br /> MW-06A 12/01/98 9.27 9.30 0.36 0.02 Measure product layer. <br /> MW-06A 2/2/1999 8.84 8.93 1.08 0.06 Measure product layer. Replace bilge bag. <br /> MW-06A 5/11/1999 9.08 9.09 0.12 0.01 Measure product layer. Replace bilge bag. <br /> MW-06A 8/10/1999 NA 8.45 0.00 0.00 No measurable product Replace bilge bag. <br /> MW-06A 11/17/1999 10 10.29 3.48 0.19 Measure product layer. Replace bilge bag. <br /> MW-06A 2/7/2000 9.63 9.67 0.48 0.03 Measure product layer. Remove and replace bilge WE <br /> MW-06A 5/9/2000 7.01 7.9 10.68 0.58 Measure product layer. Remove and replace bilge bag <br /> MW-06A 8/8/2000 19.51 19.9 4.68 0.25 Measure product layer. Remove bilge bag. <br /> MW-06A 11/8/2000 10.43 NM 0.00 0.00 Install new bilge bag. <br /> MW-06A 2/12/2001 10.35 11.99 19.7 1.07 Measure product layer. Replace bilge bag. <br /> MW-06A 5/9/2001 9.58 11.03 17.4 0.95 <br /> MW-06A 8/13/2001 9.45 10.45 12.0 0.65 <br /> MW-06A 11/19/2001 10.42 12.38 23.5 1.28 <br /> MW-06A 3/5/2002 9.95 11.71 21.1 1.15 <br /> MW-06A 11/18/2002 10.49 10.82 4.0 0.22 <br /> MW-06A 3/24/2003 10.31 10.67 4.3 023 <br /> MW-06A 11/10/2003 10.60 10.86 3.12 0.17 <br /> MW-06A 1/5/2004 10.09 11.03 11.28 0.61 Removed socks on Dec 15 <br /> MW-06A 1/15/2004 10.20 11.00 9.60 0.52 Replaced socks <br /> MW-06A 3/22/2004 10.30 11.14 10.08 0.55 Removed socks on Feb 23 <br /> MW-06A 3/31/2004 10.22 11.09 10.44 0.57 Replaced socks <br /> MW-06A 7/26/2004 9.32 10.1 9.36 0.51 Replace sock <br /> MW-06A 7/29/2004 NM NM NM NM Replace sock <br /> MW-06A 8/16/2004 NM NM NM NM Sock fell in well <br /> MW-06A 8/23/2004 NM NM NM NM Sock still in well <br /> MW-06A 9/10/2004 10.60 11.25 7.80 0.42 Install sock <br /> MW-06A 9/29/2004 10.65 11.2 6.60 0.36 Replace sock <br /> MW-06A 10/14/2004 10.62 11.1 5.76 0.31 Remove sock for sampling <br /> MW-06A 11/1/2004 10.53 10.% 5.16 0.28 <br /> MW-06A 11/12/2004 10.35 10.95 7.20 0.39 Install sock <br /> MW-06A 12/3/2004 10.65 11.25 720 0.39 Replace sock <br /> MW-06A 12/13/2004 10.63 11.3 8.04 0.44 Replace sock <br /> MW-06A 1/4/2005 9.84 10.43 7.08 0.39 Replace sock <br /> MW-06A 1/19/2005 9.93 10.51 6.96 0.38 Replace sock <br /> MW-06A 2/1/2005 9.90 10.4 6.00 0.33 Replace sock <br /> MW-06A 2/16/2005 9.33 9.9 6.84 0.37 Remove sock for sampling <br /> ERM Page 1 of 16 UPRR/0020500.56-8/24/2006 <br />
The URL can be used to link to this page
Your browser does not support the video tag.