Laserfiche WebLink
r 1 <br /> `-PAGE TWO - SAN .JOAQU I N F-"..'� I- -NMENTAL HELALTH <br /> Coi <br /> A SOIL SAMPLE DIRECTLY UNDER THE LEAKING AREA. WE CONTACTED WATERWORK IN ESCALON <br /> WHO DIRECTED A GEOLOGIST TO THE SITE IN ORDER THAT SAMPLES BE TAKEN PROPERLY. <br /> AN AUGER BORING INDICATED DETECTABLE ODOR AT A CONSIDERABLE DEPTH UNDER THE <br /> LINE LEAK. ANOTHER SAMPLE WAS THEN TAKEN IN THE EXISTING TRENCH TO THE SOUTH. <br /> THIS SAMPLE REVEALED ONLY A SLIGHT ODOR AT 4-6 FEET. IT WAS THEN FELT THAT <br /> THE PLUME PROBABLY WAS VERY CONCENTRATED IN THE PROXIMITY OF THE LEAKING LINE. <br /> THE SOIL SAMPLES WERE SENT FOR ANALYSIS. <br /> BATALLION CHIEF UEHLING WAS AGAIN ON SITE AT THE END OF THE DAY AND OBSERVED <br /> THE CORRODED PIPE SECTION AS WELL AS THE REPAIR, HE INDICATED TO THE OWNER THAT <br /> THE FIRE HAZARD HAD BEEN MITIGATED AND INDICATED THAT THE MINI MART STORE COULD <br /> BE REOPENED. FALCONS CREW THEN REMOVED THE MATERIAL' WHICH HAD BEEN EXCAVATED <br /> BY OTHERS TO AN AREA SOUTH OF THE MINI MART AND OUT OF TRAFFIC. THIS EXCAVATED <br /> MATERIAL WAS PLACED AND AND COVERED BY HEAVY PLASTIC. THE TRENCH WAS CLOSED WITH <br /> PLYWOOD AND BARRACADES PUT IN PLACE WITH CAUTION TAPE. <br /> THE OWNER OF THE STATION, MR. BRAR, HAS AT ALL TIMES BEEN COOPERATIVE IN <br /> TAKING ACTION TO MITIGATE ANY DANGEROUS CONDITION. AFTER EXPLAINING THAT THE <br /> CONTAMINATED SOIL NEEDED A SITE REMEDIATION PLAN, HE AUTHORIZED A PREPARATION <br /> THEREOF FOR SUBMISSION TO SAN .JOAQUIN COUNTY ENVIRONMENTAL HEALTH DIVISION. IN <br /> THAT REGARD, VIATERWORK IN ESCALON HAS BEEN ENGAGED AS THE CONSULTANT. IN ORDER <br /> THAT THE STATION REMAIN OPEN FOR BUSINESS PRIOR TO REMEDIATION TAKING PLACE, <br /> WE HEREWITH SUBMIT THE FOLLOWING WORKPLAN WHICH WE CONSIDER A TEMPORARY MEASURE <br /> PRIOR TO THE PERMANENT SITE REMEDIATION PLAN BEING APPROVED. <br /> TEMPORARY SITE WORK PLAN <br /> {1} HAVE UNLEADED LINE WHICH WAS REPAIRED PRESSURE TESTED . <br /> (A) INTEGRITY TANK TESTING SYSTEMS, INC. (STATE LICENSED AND CERTIFIED) <br /> 166 FRANK WEST CIRCLE <br /> STOOC80ONN, CALIFORNIA <br /> 466 36 <br /> INTEGRITY HAS BEEN ENGAGED TO PRESSURE TEST THIS LINE ON TUESDAY, 26 FEBRUARY, <br /> 1991. MR. BILL SAVAGE AT INTEGRITY HAS BEEN INSTRUCTED TO TELEPHONE MR. <br /> WILSON OR MRS. FOLEY AT THE CONCLUSION OF HIS TEST TO REPORT THE RESULTS. <br /> (Z) HAVE TWO BORINGS GROUTED UNDER PERMIT <br /> (A) CLARK WELL (LICENSED) <br /> 2024 EAST CHARTER 14AY <br /> STOCKTON, CALIFORNIA <br /> 462 7676 <br /> CLARK WELL HAS BEEN ENGAGED TO OBTAIN THE PROPER PERMIT AND MAKE THE NECESSARY 1 <br /> APPOINTMENT TO GROUT THESE 'TWO BORINGS. MIKE CLARK WILL SUPERVISE. <br /> (3) PRESSURE TEST RESULTS <br /> (A) FAVORABLE; IF LINE IS SOUND, WE PROPOSE TO FILL THE TRENCH WITH-SAND AND <br />