26 October 2000 <br /> AGE-NC Project No 95-0128 <br /> Page 9 of 10 <br /> 44 GROUND WATER EXTRACTION ACTIVITIES <br /> Ground water will be extracted from the extraction well (EW-1) and potentially from soil vapor <br /> extraction well VW-1 and ground water monitoring well MW-6, if necessary, (Figure 5) utilizing <br /> submersible, 4-inch (2-inch for monitoring wells) diameter Grundfos Rediflow self-priming <br /> downhole pumps Each pump which will be outfitted with automated electronic shut-off controls to <br /> control water entering the system During the pumping operation, the estimated ground water <br /> extraction flow rate will be betwee four and six GPM if multiple wells are used AGE anticipates <br /> total ground water extraction flow between r ean four GPM from an individual well, therefore <br /> sur e pum in i Ile ma well head if multiple wells are utilized, to <br /> control the volume of produced water <br /> From each well head, extracted ground water will be routed through a sediment pre-filter and into <br /> a 750-gallon holding tank, from which it will pass through a process pump, to the closed-loop air <br /> stripper and finally the GAC vessel The air-stripper is designed to volatilize as much diesel and <br /> gasoline compounds as possible prior to introduction into the GAC treatment, intended specifically <br /> to adsorb MTBE The exhaust from the air-stripper is designed collected volatilize hydrocarbons <br /> through carbon adsorption <br /> Sample ports will be located in appropriate position after the air-stripper, after the GAC vessel and <br /> on the air-stripper exhaust for monitoring purposes A generalized design of the treatment system <br /> is depicted in Figure 5 <br /> 4 4 1 Ground Water Extraction Piping System <br /> A network of three-inch diameter, schedule 80 PVC piping will be installed in a trench <br /> approximately '/z foot wide by 1'/7 feet deep PVC schedule 80 PVC conduits for pump power will <br /> also be installed within the trench The PVC piping will be routed from each ground water extraction <br /> well head to a water holding tank, the holding tank will be connected to the air-stripper and the <br /> piping will be directly connected to the GAC ground water treatment system A plan of the proposed <br /> piping system and enclosed unit location are depicted in Figure 5 The PVC piping will be installed <br /> on the ground water monitoring wells in preparation for potential future extraction <br /> At the direction of the property owner and due to property use constraints,the location of the ground <br /> water pump and treat system is proposed to be at the southwest corner of the site (Figure 5) This <br /> proposed location of the pump and treat system will allow the site to conduct their day-to-day <br /> business without interference from the operation of the remediation system The pump and treat <br /> system will be secured by a chain-linked, gated enclosure will be approximately 15 feet wide 20 feet <br /> long and six feet high <br /> Advanced GeoEnNtronmental,Inc <br />