Laserfiche WebLink
Appendix VI <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited:Chapter 6.7, Health and Safety Code; Chapter 16, Division 3,Title 23,California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for <br /> each monitoring system control panel by the technician who performs the work.A copy of this form must be provided to the tank system <br /> owner/operator.The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility Name: JESSE & KUL PETRO - ARCO Bldg.No.: <br /> Site Address: 1711 E. YOSEMITE AVE City: MANI'ECA, CA Zip: 95336 <br /> Facility Contact Person: Contact Phone No.: ( ) <br /> Make/Model of Monitoring System: VEEDER ROOT TLS-350 Date of Testing/Servicing: 6/13/2016 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appro, nate boxes to indicatespecific a ui ment inspected/serviced: <br /> Tank ID: 87 Tank Size: 15 K Tank ID: 87-2 Tank Size: 15 K <br /> E In-Tank Gauging Probe. Model: MAG 1 E In-Tank Gauging Probe. Model: MAG I <br /> E Annular Space or Vault Sensor. Model: 4 0 9 E Annular Space or Vault Sensor. Model: 4 0 9 <br /> E Piping Sump/Trench Sensor(s). Model: 32 3 E Piping Sump/Trench Sensor(s). Model: 3 2 3 <br /> E Fill Sump Sensor(s). Model: 3 2 3 E Fill Sump Sensor(s). Model: 20 8 <br /> ❑ Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br /> ISI Electronic Line Leak Detector. Model: P L L D E Electronic Line Leak Detector. Model: SHARED LINE <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: Tank Size: Tank ID: 91 Tank Size: 12 K <br /> ❑ In-Tank Gauging Probe. Model: E In-Tank Gauging Probe. Model: MAG I <br /> ❑ Annular Space or Vault Sensor. Model: E Annular Space or Vault Sensor. Model: 4 0 9 <br /> ❑ Piping Sump/Trench Sensor(s). Model: E Piping Sump/Trench Sensor(s). Model: 3 2 3 <br /> ❑ Fill Sump Sensor(s). Model: E Fill Sump Sensor(s). Model: 32 3 <br /> ❑ Mechanical Line Leak Detector. Model: E Mechanical Line Leak Detector. Model: 99 LD 2000 <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: 1 / 2 Dispenser ID: 3 / 4 <br /> ® Dispenser Containment Sensor(s). Model: 3 2 3 ® Dispenser Containment Sensor(s). Model: 3 2 3 <br /> E Shear Valve(s). ® Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5 / 6 Dispenser ID: 7 / 8 <br /> ® Dispenser Containment Sensor(s). Model: 3 2 3 E Dispenser Containment Sensor(s). Model: 3 2 3 <br /> E Shear Valve(s). E Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> Model ❑ Dispenser Containment <br /> ❑ Dispenser Containment Sensor(s). Sensor(s). Model: <br /> ❑ Shear Valve(s). ❑Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> 'If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines.Attached to this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct <br /> and a Plot Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached a <br /> copy of the report;(check all that app&): E System set-up ®Alarm history report <br /> Technician Name(print): ZANE NIMMO Signature: <br /> Certification No.: A28446 License No: 04-1676 <br /> Testing Company Name: AFFORDA-TEST Phone No. (209)744-0113 <br /> Testing Company Address: 416 2n'STREET GALT,CA 95632 Date of Testing/Servicing: 6/13/2016 <br /> Monitoring System Certification Page 1 of 4 2/21/07 <br />