My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1711
>
2300 - Underground Storage Tank Program
>
PR0231455
>
COMPLIANCE INFO_2013 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/6/2020 1:54:57 PM
Creation date
5/5/2020 4:53:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2018
RECORD_ID
PR0231455
PE
2361
FACILITY_ID
FA0003612
FACILITY_NAME
Yosemite Avenue Arco AmPm
STREET_NUMBER
1711
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
Ave
City
Manteca
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
1711 E Yosemite Ave
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
459
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209) 468-3433 Web:www.sogov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Yosemite Avenue Arco AmPm 1 1711 E Yosemite Ave Manteca ]June 13 2016 <br /> UST System Observations <br /> 326 CCR 2631.1 UST system not compatible with the substance stored 1 V u R ❑COS <br /> 327 HSC 25298(b) Failed to comply with temporary closure requirements c V c R c COS <br /> 328 HSC 25298(c) Failed to comply with permanent closure requirements ❑V c R c COS <br /> 329 CCR 2636(f)(6) Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system V c R c COS <br /> Non-Pressurized Piping <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve ijV c R c COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed c V c R c COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) c V c R c COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) ❑V n R n COS <br /> Other Violations <br /> 2010 See below Unlisted Administration/Documentation violation c V c R c COS <br /> 2030 See below Unlisted Operations/Maintenance violation c V c R c COS <br /> 2060 See below Unlisted Design/Construction violation c V c R c COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS Il,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 104 CCR 2711 UST Operating Permit Application for Facility and Tank information not submitted or current. <br /> UST Tank Information forms for: TA0508451, TA0508481, and TA0508482, are not current in CERS. Below TANK <br /> DESCRIPTION, add information for TANK MANUFACTURER AND DATE UST SYSTEM INSTALLED. Information at <br /> the San Joaquin County Environmental Health Department(EHD) indicates that all three tanks were manufactured by <br /> Xerxes and installed in April 1999. Any change of information must be updated in CERS within 30 days of the <br /> changes. Immediately log into CERS, update the required information, and submit for review by the EHD. <br /> This is a Class II violation. <br /> 105 CCR 2632 Monitoring and response plans not current or approved by the EHD. <br /> The monitoring plan is not current and/or not approved by the EHD. For tank ID No. TA0508481, belowr PIPE <br /> MONITORING IS PERFORMED USING THE FOLLOWING METHOD, change the LEAK SENSOR MODEL from 208 <br /> to 323, and below UNDER DISPENSER CONTAINMENT(UDC) MONITORING, change UDC LEAK SENSOR MODEL <br /> from 208 to 323. For all three underground storabe tanks (USTs), below RECORDKEEPNG, change"No"to"Yes"for <br /> VISUAL INSPECTION RECORDS; and for all three USTs, below TRAINING, change"No" to"Yes"for PERSONNEL <br /> WITH UST MONITORING RESPONSIBILITIES ARE FAMILIAR WITH TRAINING DOCUMENTS. The monitoring plan <br /> must be uploaded to the California Environmental Reporting System (CERS). Immediately log into CERS, make the <br /> necessary changes, and submit for review by the EHD. <br /> This is a minor violation. <br /> Page 3 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.