My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1711
>
2300 - Underground Storage Tank Program
>
PR0231455
>
COMPLIANCE INFO_2013 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/6/2020 1:54:57 PM
Creation date
5/5/2020 4:53:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2018
RECORD_ID
PR0231455
PE
2361
FACILITY_ID
FA0003612
FACILITY_NAME
Yosemite Avenue Arco AmPm
STREET_NUMBER
1711
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
Ave
City
Manteca
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
1711 E Yosemite Ave
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
459
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Monitoring System Certification <br /> L) <br /> P. Results of Testing/Servicing JUN 16 2015 <br /> Software Version Installed: _ENVIRONMENTAL <br /> ,,rtI—,-,r+rnnnT� <br /> Com lete the folio D7 checklist- <br /> 'es ❑ No* Is the audible alarm operational? <br /> Yes ❑ No* Is the visual,alarm operational? <br /> Yes EI No* Were all sensors visually ins ected,functionally tested,and confirmed operational? <br /> Yes ❑ Noy' Were all sensors installed at lowest point of secondary contai.ntnent and positioned so that other equipment will <br /> not interfere with,their proper operation? <br /> El Ycs ❑ No* If alarms are relayed to a remote monitoring stator, is all communicatioas equipment (e.g., modem) <br /> N/A operational? <br /> Yes ❑ :N o* For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br /> ❑ N/A monitoring system detects a leak,fails to opera e,or is electrically discotyxected? If yes: -whic}r sensors initiate <br /> positive shut-down? (Check all that apply) Pr Sump/Trench Sensors; A Dispenser Cootainmem Sensors. <br /> Did you conftrm.positive shut-down due to leaks and sensor failure/disconnection? KI Yes; ❑No. <br /> Yes D No* For tank systems that utilize the monitoring system as the primary tank. overfill warning device (i.e., no <br /> El N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br /> .fill point(s)and operating properly? If so,at what percent of tank capacity does the alamr trigger?90 % <br /> ❑ Yes* No Was any nlonitoritlg equipment replaced? If yes, identify specific sensors,probes,or other equipment replaced <br /> and list the manufacturer name and model for all replacement parts in Section l',below. <br /> ❑ Yes* No Was liquid found inside any secondary containment systems designed as dry systems`.' (Cheek all shat ap( y,) <br /> ❑Product; El Water. If yes,describe causes in Section E,below. <br /> Yes ❑ No* Was moryitpring system set-u .reviewed to ensure er settings?Attach set u reports,if applicable <br /> kA Yes ❑ No* Is all nnoni.toAng equipment operational.per <br /> manufacturer's specifications? <br /> * In Section 1F below,describe how and when tbese deficiencies were or will be corrected. <br /> E. Comments: <br /> TJN-036-316 ww.v.nnidgc6.org Rev.0t11.7/08 <br />
The URL can be used to link to this page
Your browser does not support the video tag.