My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1711
>
2300 - Underground Storage Tank Program
>
PR0231455
>
COMPLIANCE INFO_2013 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/6/2020 1:54:57 PM
Creation date
5/5/2020 4:53:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2018
RECORD_ID
PR0231455
PE
2361
FACILITY_ID
FA0003612
FACILITY_NAME
Yosemite Avenue Arco AmPm
STREET_NUMBER
1711
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
Ave
City
Manteca
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
1711 E Yosemite Ave
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
459
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONI )RING SYSTEM CERTIF ''ATION <br /> For Use By All Jurisdictions Within the State of Cai jrornia <br /> Authority Cited.• Chapter 6.7, Health and Safety Code;Chapter 16, Division 3, Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. A se ar a' e be prepared for each <br /> monitoring system control panel by the technician who performs the work. A copy of this form 16dLLa%L04Wt1.1fiL%Ustem owner/operator. <br /> The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information JUL 2 2014 <br /> Facility Name: Arco ENVIRONMENT.1 H No.: <br /> Site Address: 1711 E.Yosemite Ave. City: MantecaPERMIT/SERVICES ip: 95336 <br /> Facility Contact Person: Sonnie Contact Phone No.: (209) 451-8441 <br /> Make/Model of Monitoring System: Veeder Root TLS-350 Date of Testing/Servicing: 6/4/2014 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific equipment inspected/serviced: <br /> Tank ID: T1: 87 Master Tank ID: T2: 87 Slave <br /> ®In-Tank Gauging Probe. Model: 847390-109 ®In-Tank Gauging Probe. Model: 847390-109 <br /> ®Annular Space or Vault Sensor. Model: 794390-409 ®Annular Space or Vault Sensor. Model: 794390-409 <br /> ®Piping Sump/Trench Sensor(s). Model: 794380-323 ®Piping Sump/Trench Sensor(s). Model: 794380-323 <br /> ®Fill Sump Sensor(s). Model: 794380-208 ®Fill Sump Sensor(s). Model: 794380-323 <br /> ❑Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: <br /> ® Electronic Line Leak Detector. Model: 8484 ❑Electronic Line Leak Detector. Model: <br /> ❑Tank Overfill/High-Level Sensor. Model: ❑Tank Overfill/High-Level Sensor. Model: <br /> ❑Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: T3: 91 Tank ID: <br /> ®In-Tank Gauging Probe. Model: 847390-109 ❑In-Tank Gauging Probe. Model: <br /> ®Annular Space or Vault Sensor. Model: 794390-409 ❑Annular Space or Vault Sensor. Model: <br /> ®Piping Sump/Trench Sensor(s). Model: 794380-323 ❑Piping Sump/Trench Sensor(s). Model: <br /> ®Fill Sump Sensor(s). Model: 794380-323 ❑Fill Sump Sensor(s). Model: <br /> ®Mechanical Line Leak Detector. Model: 99LD-2000 ❑Mechanical Line Leak Detector. Model: <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> ❑Tank Overfill/High-Level Sensor. Model: ❑Tank Overfill/High-Level Sensor. Model: <br /> ❑Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: 182 Dispenser ID: 384 <br /> ®Dispenser Containment Sensor(s). Model: 794380-323 ®Dispenser Containment Sensor(s). Model: 794380-323 <br /> ®Shear Valve(s). ®Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 586 Dispenser ID: 788 <br /> ®Dispenser Containment Sensor(s). Model: 794380-323 ®Dispenser Containment Sensor(s). Model: 794380-323 <br /> ®Shear Valve(s). ®Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> ❑Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> ❑Shear Valve(s). ❑Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> *lythe facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the <br /> manufacturers' guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this <br /> information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such <br /> reports,I have also attached a copy of the report;(check all that apply): ® System set-up ®Alarm history report <br /> Technician Name(print): Guadalupe Sanchez Signatu • <br /> Certification No.: A30138 License.No.: 883706 <br /> Testing Company Name: Reliable Petroleum Services, Inc. Phone No.: (209) 845-8586 <br /> Testing Company Address: 11930 Horseshoe Rd. Oakdale, Ca.95361 Date of Testing/Servicing: 6/4/2014 <br /> Page 1 of 4 <br /> Rev(2/08) <br />
The URL can be used to link to this page
Your browser does not support the video tag.