My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1711
>
2300 - Underground Storage Tank Program
>
PR0231455
>
COMPLIANCE INFO_2013 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/6/2020 1:54:57 PM
Creation date
5/5/2020 4:53:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2018
RECORD_ID
PR0231455
PE
2361
FACILITY_ID
FA0003612
FACILITY_NAME
Yosemite Avenue Arco AmPm
STREET_NUMBER
1711
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
Ave
City
Manteca
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
1711 E Yosemite Ave
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
459
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Reliable Petcolevm Services, Inc. L,� <br /> R 3:SUPER STP Pap / Of <br /> TYPE: <br /> STANDARD <br /> -- NORMALLY CLOSED <br /> R 2:MID.STP <br /> TYPE: TANK #: 3 <br /> STANDARD RECONCILIATION SETUP <br /> NORMALLY CLOSED - - - - - - - - - - - - <br /> IN-TANK ALARMS <br /> TANK #: 2 T 3:HIGH WATER ALARM EMM 1 : G <br /> T 3:LOW PRODUCT ALARM AUTOMATIC DAILY CLOSING <br /> IN-TANK ALARMS LIQUID SENSOR ALMS TIME: 12:00 AM <br /> T 2:HIGH WATER ALARM L 1 :FUEL ALARM <br /> T 2:LOW PRODUCT ALARM L 2:FUEL ALARM AUTO SHIFT #1 CLOSING <br /> L 3:FUEL ALARM TIME: DISABLED <br /> LIQUID SENSOR ALMS L 4:FUEL ALARM <br /> L 1 :FUEL ALARM L 5:FUEL ALARM AUTO SHIFT #2 CLOSING <br /> L 2:FUEL ALARM L 6:FUEL ALARM TIME: DISABLED <br /> L 3:FUEL ALARM L 7:FUEL ALARM <br /> L 4:FUEL ALARM L 8:FUEL ALARM AUTO SHIFT #3 CLOSING <br /> L 5:FUEL ALARM L12:FUEL ALARM TIME: DISABLED <br /> L 6:FUEL ALARM L15:FUEL ALARM <br /> L 7:FUEL ALARM L 1 :SENSOR OUT ALARM AUTO SHIFT #4 CLOSING <br /> L 8:FUEL ALARM L 2:SENSOR OUT ALARM TIME: 12:00 AM <br /> L12:FUEL ALARM L 3:SENSOR OUT ALARM <br /> L15:FUEL ALARM L 4:SENSOR OUT ALARM <br /> L 1 :SENSOR OUT ALARM L 5:SENSOR OUT ALARM PERIODIC RECONCILIATION <br /> L 2:SENSOR OUT ALARM L 6:SENSOR OUT ALARM MODE: MONTHLY <br /> L 3:SENSOR OUT ALARM L 7:SENSOR OUT ALARM ALARM: DISABLED <br /> L 4:SENSOR OUT ALARM L B:SENSOR OUT ALARM <br /> L 5:SENSOR OUT ALARM L12:SENSOR OUT ALARM TEMP COMPENSATION <br /> L 6:SENSOR OUT ALARM L15:SENSOR OUT ALARM STANDARD <br /> L 7:SENSOR OUT ALARM L 1 :SHORT ALARM METER CALIBRATION <br /> L 8:SENSOR OUT ALARM L 2:SHORT ALARM OFFSET: 0.000°x; <br /> L12:SENSOR OUT ALARM L 3:SHORT ALARM <br /> L15:SENSOR OUT ALARM L 4:SHORT ALARM BUS SLOT FUEL METER TANK. <br /> L 1 :SHORT ALARM L 5:SHORT ALARM - - - - - - - - - - - - <br /> L 2:SHORT ALARM L 6:SHORT ALARM TANK MAP EMPTY <br /> L 3:SHORT ALARM L 7:SHORT ALARM <br /> L 4:SHORT ALARM L B:SHORT ALARM SMARTSENSOR SETUP <br /> L 5:SHORT ALARM L12:SHORT ALARM - - - - - - - - - - - - <br /> L 6:SHORT ALARM L15:SHORT ALARM <br /> L 7:SHORT ALARM s 1 :AFM 1-2 <br /> L 8:SHORT ALARM CATEGORY AIR FLOW METER <br /> L12:SHORT ALARM ISD SITE ALARMS <br /> L15:SHORT ALARM ISD GROSS PRES FAIL s 2:AFM 3-4 <br /> ISD DEGRD PRES FAIL CATEGORY AIR FLOW METER <br /> ISD VAPOR LEAK FAIL <br /> ISD SITE ALARMS ISD VP PRES FAIL = 3:AFM 5-6 <br /> ISD GROSS PRES FAIL ISD VP STATUS FAIL 'CATEGORY AIR FLOW METER <br /> ISD DEGRD PRES FAIL <br /> ISD VAPOR LEAK FAIL ISD HOSE ALARMS s 4:AFM 7-8 <br /> ISD VP PRES FAIL ALL:GROSS COLLECT FAIL CATEGORY AIR FLOW METER <br /> ISD VP STATUS FAIL ALL:DEGRD COLLECT FAIL <br /> s 5:AFM 9-10 <br /> ISD HOSE ALARMS R 4:OVERFILL CATEGORY AIR FLOW METER <br /> ALL:GROSS COLLECT FAIL TYPE: <br /> ALL:DEGRD COLLECT FAIL STANDARD s 6:AFM 11-12 <br /> .:r <br /> NORMALLY OPEN CATEGORY AIR FLOW METER <br /> TANK #: NONE s 7:AFM 13-14 <br /> CATEGORY AIR FLOW METER <br /> NO ALARM ASSIGNMENTS - <br /> s 9:AFM 15-16 <br /> CATEGORY AIR FLOW METER <br /> s10:VAPOR PRESS. <br /> CATEGORY VAPOR PRESSURE <br /> PLLD LINE DISABLE SETUP <br />
The URL can be used to link to this page
Your browser does not support the video tag.