Laserfiche WebLink
L a:U1�Y. r-a <br /> ` TRI-STATE (SINGLE FLOAT) ',UTPUT RELAY SETUP <br /> CATEGORY : DISPENSER PAN - - - - - - - - - - - <br /> 1 :REG. STP <br /> PE: <br /> L 5:DISP.9-10 MOMENTARY <br /> TRI-STATE (SINGLE FLOAT) tORMALLY CLOSED NK #: 2 <br /> CATEGORY : DISPENSER PAN <br /> IN-TANX ALARMS IN-TANK ALARMS <br /> T 1 :HIGH WATER ALARM T 2:HIGH WATER ALARM <br /> L 6:DISP. 11-1 T 1 :LOW PRODUCT ALARM C 2:LOW PRODUCT ALARM <br /> TRI-STATE (SING'LE FLOAT) <br /> CATEGORY : DISPEN:3ER PAN LIQUID SENSOR ALMS LIQUID SENSOR ALMS <br /> L 1 :FUEL ALARM L 1 :FUEL ALARM <br /> L 2:FUEL ALARM L 2:FUEL ALARM <br /> L 3:FUEL ALARM L 3:FUEL ALARM <br /> L 7:DISP.13-14 L 4:FUEL ALARM L 4:FUEL ALARM <br /> TRI-STATE (SINGLE FLOAT) L 5:FUEL ALARM L 5:FUEL ALARM <br /> CATEGORY : DISPENSER PAN L 6:FUEL ALARM L 6:FUEL ALARM <br /> L 7:FUEL ALARM L 7:FUEL ALARM <br /> L B:FUEL ALARM L 8:FUEL ALARM <br /> L 9:FUEL ALARM L12:FUEL ALARM <br /> L 8:DISP.15-16 L 1 :SENSOR OUT ALARM L15:FUEL ALARM <br /> TRI-STATE (SINGLE FLOAT) L 2:SENSOR OUT ALARM L 1 :SENSOR OUT ALARM <br /> CATEGORY : DISPENSER PAN L 3:SENSOR OUT ALARM L 2:SENSOR OUT ALARM <br /> L 4:SENSOR OUT ALARM L 3:SENSOR OUT ALARM <br /> L 5:SENSOR OUT ALARM L 4:SENSOR OUT ALARM <br /> L 6:SENSOR OUT ALARM L 5:SENSOR OUT ALARM <br /> 9:REG. STP L 7:SENSOR OUT ALARM L 6:SENSOR OUT ALARM <br /> IXI-STATE (SINGLE FLOAT) L 8:SENSOR OUT ALARM L 7:SENSOR OUT ALARM <br /> CATEGORY : STP SUMP L 9:SENSOR OUT ALARM L 8:SENSOR OUT ALARM <br /> L 1 :SHORT ALARM L12:SENSOR OUT ALARM <br /> L 2:SHORT ALARM L15:SENSOR OUT ALARM <br /> O:REG.FILL L 3:SHORT ALARM L 1 :SHORT ALARM <br /> I-STATE (SINGLE FLOAT) L 4:SHORT ALARM L 2:SHORT ALARM <br /> fEGORY : PIPING SUMP L 6:SHORT ALARM L 3:SHORT ALARM <br /> L 6:SHORT ALARM L 4:SHORT ALARM <br /> L 7:SHORT ALARM L 5:SHORT ALARM <br /> 1.11 :REG.ANNULAR L B:SHORT ALARM L 6:SHORT ALARM <br /> TRI-STATE (SINGLE FLOAT) L 9:SHORT ALARM L 7:SHORT ALARM <br /> HTEGORY : ANNULAR SPACE L 8:SHORT ALARM <br /> ISD SITE ALARMS L12:SHORT ALARM <br /> ISD GROSS PRES FAIL L15:SHORT ALARM <br /> ISD DEGRD PRES FAIL <br /> L12:MID.STP <br /> TRI-STATE (SINGLE FLOAT) ISD VAPOR LEAK FAIL ISD SITE ALARMS <br /> CATEGORY : STP SUMP ISD VP PRES FAIL ISD GROSS PRES FAIL <br /> ISD VP STATUS FAIL ISD DEGRD PRES FAIL <br /> L13:MID.FILL SD HOSE ALARMS ISD VAPOR LEAK FAIL <br /> ISD VP PRES FAIL <br /> TRI-STATE (SINGLE FLOAT) ALL:GROSS COLLECT FAIL <br /> ISD VP STATUS FAIL <br /> CATEGORY : PIPING SUMP ALL:DEGRD COLLECT FAIL <br /> .51) HOSE ALARMS <br /> R 2:MID.STP ALL:GROSS COLLECT FAIL <br /> L14:MID.ANNULAR YPE: ALL:DEGRD COLLECT FAIL <br /> TRI-STATE (SINGLE FLOAT) STANDARD <br /> CATEGORY : ANNULAR SPACE RMALLY CLOSED 3:SUPER STP <br /> PE: <br /> STANDARD <br /> L15:SUPER STP RMALLY CLOSED <br /> TRI-STATE (SINGLE FLOAT) <br /> CATEGORY STP SUMP <br /> L16:SUPER FILL <br /> TRI-STATE (SINGLE FLOAT) <br /> CATEGORY PIPING SUMP <br /> L17:SUPER ANNULAR <br /> TRI-STATE (SINGLE FLOAT) <br /> CATEGOR`! : ANNULAR SPACE <br />