Laserfiche WebLink
LEHK MIN PERIODIC: 33% MEi_HriNIC(I'L BLENDED: 1-10 L14:MID.ANNULAR <br /> 3910 TRI-STATE (SINGLE FLOAT) <br /> LEAK MIN ANNUAL 50% CATEGORY ANNULAR SPACE <br /> 5924 <br /> PERIODIC TEST TYPE L15:SUPER STP <br /> STANDARD TRI-STATE (SINGLE FLOAT) <br /> CATEGORY STP SUMP <br /> ANNUAL TEST FAIL <br /> ALARM DISABLED <br /> L16:SUPER FILL <br /> PERIODIC TEST FAIL LINE LEAK LOCKOUT SETUP TRI-STATE (SINGLE FLOAT) <br /> ALARM DISABLED - - - - - - - - - - - - CATEGORY PIPING SUMP <br /> LOCKOUT SCHEDULE <br /> GROSS TEST FAIL DAILY <br /> ALARM DISABLED START TIME: DISABLED L17:SUPER ANNULAR <br /> STOP TIME : DISABLED TRI-STATE (SINGLE FLOAT) <br /> ANN TEST AVERAGING: OFF CATEGORY ANNULAR SPACE <br /> PER TEST AVERAGING: OFF <br /> TANK TEST NOTIFY: OFF <br /> TNK TST SIPHON BREAKOFF <br /> DELIVERY DELA`! 3 MIN <br /> PUMP THRESHOLD 10.00° <br /> LIQUID SENSOR SETUP <br /> OUTPUT RELAY SETUP <br /> L 1 :DISP.1-2 - - - - - - - - - - - - <br /> TRI-STATE (SING'LE FLOAT) <br /> CATEGORY : DISPENSER PAN R 1 :REG. STP 2 <br /> TYPE: <br /> PUMP CONTROL OUTPUT <br /> TANK 0: 2 <br /> LEAK TEST METHOD L 2:DISP.3-4 <br /> TRI-STATE (SINGLE FLOAT) <br /> TEST ON DATE : ALL TANK CATEGORY : DISPENSER PAN IPJ-TANK ALARMS <br /> OCT 9, 2008 T 2:HIGH WATER ALARM <br /> START TIME : DISABLED T 2:L0W PRODUCT ALARM <br /> TEST RATE :0.20 GAL/HR LIQUID SENSOR ALMS <br /> DURATION 2 HOURS L 3:DISP.5-6 <br /> TRI-STATE (SINGLE FLOAT) L 1 :FUEL ALARM <br /> TST EARLY STOP:DISABLED CATEGORY : DISPENSER PAN L 2:FUEL ALARM <br /> L 3:FUEL ALARM <br /> LEAK TEST REPORT FORMAT L 4:FUEL ALARM <br /> NORMAL L 5:FUEL ALARM <br /> L 4:DISP.7-8 L 6:FUEL ALARM <br /> TRI-STATE (SINGLE FLOAT) L 7:FUEL ALARM <br /> CATEGORY : DISPENSER PAN L B:FUEL ALARM <br /> L 9:FUEL ALARM <br /> L12:FUEL ALARM <br /> L 1 :SENS0R OUT ALARM <br /> L 9:REG. STP L 2:SENS0R OUT ALARM <br /> TRI-STATE (SINGLE FLOAT) L 3:SENS0R OUT ALARM <br /> CATEGORY : STP SUMP L 4:SENS0R OUT ALARM <br /> L 5:SENS0R OUT ALARM <br /> L 6:SENS0R OUT ALARM <br /> PRESSURE LINE LEAK SETUP L1O:REG.FILL L 7:SENS0R OUT ALARM <br /> - - - - - - - - - - - - TkI-STATE (SINGLE FLOAT) L 8:SENS0R OUT ALARM <br /> CATEGORY : PIPING SUMP L 9:SENS0R OUT ALARM <br /> L12:SENSOR OUT ALARM <br /> Q 1 :UNLEAD L 1 :SHORT ALARM <br /> L11 :REG.ANNULAR L 2:SHORT ALARM <br /> TYP:2.Oa3.0IN FIBERGLASS TRI-STATE (SINGLE FLOAT) L 3:SHORT ALARM <br /> 2.OIN DIA LEN: 250 FEET CATEGORY : ANNULAR SPACE L 4:SHORT ALARM <br /> L 5:SHORT ALARM <br /> 3.OIN DIA LEN: 0 FEET L. 6:SHORT ALARML 7:SHORT ALARM <br /> SHUTDOWN RATE: 3.0 GPH L12:MID.STP L 8:SHORT ALARM <br /> LOW PRESSURE SHUTOFF:NO TRI-STATE (SINGLE FLOAT) L 9:SHORT ALARM <br /> LOW PRESSURE : 0 PSI CATEGORY : STP SUMP L12:SH0RT ALARM <br /> T 1 :UNLEADED R <br /> DISPENSE MODE: L13:MID.FILL <br /> MANIFOLDED: ALTERNATE TRI-STATE (SINGLE FLOAT) PRESSURE LINE LEAK <br /> SENSOR: NON-VENTED CATEGORY : PIPING SUMP Q 1 :GROSS LINE FAIL <br /> PRESSURE OFFSET: O.OPSI <br />