Laserfiche WebLink
F <br /> KEI-P89-1104 .QR1 <br /> April 191 1991 <br /> r Page 2 <br /> KEI returned to the site on November 20, 1989 in order to collect <br /> soil samples from the on-site product pipe trenches. Four samples, <br /> labeled P1 through P4 , were collected from the product pipe <br /> trenches. Two samples, labeled VPI and VP2 , were collected from <br /> the vapor pipe trenches, and one sample, labeled WP1, was collected <br /> from the waste oil remote fill pipe trench. All seven soil samples <br /> were collected at depths ranging from 2 . 5 to 3 . 5 feet. Pipe trench <br /> sample point locations are as shown on the attached Site Plan, <br /> Figure 4 . <br /> In an attempt to remove as much of the contaminated soil as <br /> possible in the fuel tank pit, KEI returned to the site on December <br /> 5, 1989 to observe additional soil excavation in the area of sample <br /> points A2 and B2 as described in KEI 's work plan (KEI-P89-1104 .P1) <br /> dated November 22 , 1989 . Soil was excavated from the southerly <br /> half of the fuel tank pit to a depth of 26 . 5 feet. Two soil <br /> samples, labeled A2 (25 . 5) and B2 (26. 5) , were collected from the <br /> fuel tank pit below sample point location A2 at a depth of 25. 5 <br /> feet, and below sample point location B2 at a depth of 26. 5 feet, <br /> respectively. Four soil samples, labeled SW1 (13) , SW1 (19) , <br /> SW2 (20/13) and SW2 (20/19) , were also collected from the tank pit <br /> sidewalls at depths of 13 and 19 feet. Sample point locations are <br /> shown on the attached Site Plan, Figure 3 . Mr. Harlin Knoll of the <br /> SJCPHS was present during sampling. <br /> KEI again returned to the site on December 7 , 1989 in order to <br /> complete sampling of the southerly half of the fuel tank pit. Two <br /> soil samples, labeled SW3 (20/13) and SW3 (20/19) , were collected <br /> from the tank pit sidewalls at depths of 13 and 19 feet, respec- <br /> tively. In addition, one soil sample, labeled NSW, was collected <br /> from the northerly sidewall of the new fuel tank pit at a depth of <br /> 13 . 5 feet. Sample point locations are as shown on the attached <br /> Site Plan, Figure 3 . On December 13, 1989, KEI completed sampling <br /> of the old fuel tank pit when three sidewall soil samples, labeled <br /> SW4 (3) SW5 and SW6, were collected from the northerly half of the <br /> old fuel tank pit at a depth of approximately 16 feet. Sample <br /> point locations are shown on the attached Site Plan, Figure 3 . <br /> Also on December 13 , 1989 , four additional soil samples, labeled <br /> P1 (6) , P2 (17) , P3 (5) and P4 (8) , were collected from the product <br /> pipe trenches at sample point locations P1, P2 , P3 and P4, <br /> respectively. Sample depths ranged from 5 to 17 feet. Sample <br /> point locations are as shown on the attached Site Plan, Figure 4 . <br /> After sampling, the product pipe trenches were excavated to the <br /> sample depths. Upon review of the laboratory analyses for these <br /> samples, a 15-inch diameter casing (14 feet deep) was installed <br /> near sample point location P2 (17) . <br />