Laserfiche WebLink
r7 x <br /> KEI-P89-1104 .R1 <br /> January 8 , 1990 <br /> Page 3 <br /> feet. All samples were taken from bulk material excavated by <br /> backhoe, collected and handled as described above. These sample <br /> point locations are also shown on the attached Site Plan, Figure <br /> 2 . Mr. Harlin Knoll of the San Joaquin County Public Health <br /> Services was present during sampling. <br /> KEI again returned on December 7 , 1989 in order to complete <br /> sampling of the southerly half of the fuel tank pit. Two soil <br /> samples, labeled SW3 (20/13) and SW3 (20/19) , were collected from <br /> the tank pit sidewalls at depths of 13 and 19 feet, respectively. <br /> In addition, one soil sample, labeled NSW, was collected from the <br /> northerly sidewall of the new fuel tank pit at a depth of 13 . 5 <br /> feet. Again, all samples were taken from bulk material excavated <br /> by backhoe, collected and handled as previously described. <br /> Sample point locations are as shown on the attached Site Plan, <br /> Figure 2 . <br /> On December 13 , 1989, KEI completed sampling of the old fuel tank <br /> pit when three sidewall soil samples, labeled SW4 (3) SW5 and SW6, <br /> were collected from the northerly half of the old fuel tank pit <br /> at a depth of approximately 16 feet. Samples were taken from <br /> bulk material excavated by backhoe, collected and handled as <br /> described above. Sample point locations are shown on the <br /> attached Site Plan, Figure 2 . <br /> Also on December 13 , 1989, four additional samples of native <br /> soil , labeled P1 (6) , P2 (17) , P3 (5) and P4 (8) , were collected from <br /> the product pipe trenches at sample point locations P1, P2 , P3 <br /> and P4 , respectively. Sample depths ranged from 5 to 17 feet. <br /> Samples were collected from bulk material excavated by backhoe, <br /> taken and handled as previously described. Sample point loca- <br /> tions are as shown on the attached Site Plan, Figure 3 . After <br /> sampling, the product pipe trenches were excavated to the sample <br /> depths. Upon review of the laboratory analyses for these <br /> samples, a 15-inch diameter casing (14 feet deep) was installed <br /> near sample point location P2 (17) . <br /> After completion of the soil sampling on December 13 , 1989 , a <br /> water sample was taken from the on-site domestic well system <br /> after purging a minimum of three piping volumes. The sample was <br /> also taken only while the pump was operating to avoid drawing <br /> water from the holding tank. The sample was collected In six <br /> clean, glass VOA vials, with Teflon screw caps, sealed and <br /> handled as described above. <br />