Laserfiche WebLink
• �r <br /> Pre-Tank Relining Site Assessment Report 4 <br /> The Southland Corporation 4501 North Pershing Avenue Stockton California February 28, 1997 <br /> any of the eight soil samples collected. Total lead was"reported in four soil samples at concentrations <br /> ranging from 11 to 13 mg/kg. Copies of laboratory analyses reports and chain-of-custody manifests are <br /> included in Appendix C. <br /> 3.3 Results of Groundwater Sample Analyses <br /> Table 2 summarizes the laboratory analytical results for groundwater samples collected from soil borings, <br /> GP3, GP4, and GP7 on February 20,1997. A sheen was noted on the water sample GP4, and the sample <br /> also contained the highest concentrations of BTEX, MTBE, and TPH-G of the three sampled wells. The <br /> water sample collected from,GP3, located immediately north of the tank pit, contained significantly lower <br /> concentrations of benzene,TPH-G, and MTBE than GP4. Water sample GP-7, collected from a point <br /> located upgradient of the USTs; did.not contain concentrations of BTEX, MTBE, or TPH-G above'the <br /> laboratory reporting limit. <br /> Maximum concentrations in groundwater sample GP4 were benzene at 9,100 ug/L, TPH-G at 1.00,000 <br /> ug/L, and MTBE at 100,000 ug/I using EPA method 8020. The concentration of MTBE in sample GP4 was . <br /> confirmed using EPA method 8260 at 84,000 ug/L. Copies of laboratory analyses reports and chain-of- <br /> custody manifests are included in Appendix C. <br /> 4.0 SUMMARY AND CONCLUSION. <br /> A total of seven geoprobe points were drilled at the subject site: four angled borings to vertical depths of 15 <br /> feet under the three USTs,two vertical borings to a depth of 22 feet adjacent to the USTs, and one vertical . <br /> boring to a depth of 22 feet in the southeastern corner of the property(Figure 2). A total of eight soil <br /> samples and three groundwater samples were.collected for analysis. No TPH-G was detected in the eight <br /> soil samples analyzed; one sample contained benzene; and four samples contained'MTBE (Table 1). <br /> Elevated concentrations of benzene;MTBE, and TPH-G were detected in groundwater samples GP3 and <br /> GP4 collected immediately north and east of the USTs. The upgradient water sample GP-7 did not contain <br /> reportable concentrations of BTEX,TPH-G, or MTBE. <br /> Due to the elevated hydrocarbon concentrations in the groundwater samples collected near the USTs, an. . <br /> Underground Storage Tank Unauthorized Release (Leak)/Contamination Site Report was completed by the <br /> SJCPHS. <br /> The down-gradient and cross-gradient limits of the impacted groundwater were not defined. Since the <br /> USTs are located five feet west of the sidewalk,the impacted groundwater plume extends off site northeast <br /> of borings GP3 and GP4. <br /> 0472ASMT.RPT(Sthl-56) <br /> FLUOR DANIEL GTI <br />