Laserfiche WebLink
First Quarter 2001 Monitoring and Sampling Report 2 <br /> 7-Eleven,Inc Store No 17334,4501 North Pershing Avenue Stockton CA March 30 2001 <br />' Monitoring Well Sampling and Analytical Results <br />' Quarterly groundwater samples were collected after purging at least 4 well-casing volumes of <br /> groundwater from each monitoring well, unless the well was purged dry The groundwater samples were <br /> collected using disposable bailers Groundwater samples were placed in analysis-specific containers <br />' with analysis-specific preservative The samples were then sealed using Teflon septum caps, labeled <br /> with the fob identification number, the sample number, date,time, and type of laboratory analysis <br /> required The samples were stored on Ice and transported with a chain-of-custody record to a state- <br /> certified laboratory for analysis Groundwater samples were analyzed for BTEX and TPH-G using <br /> Environmental Protection Agency (EPA) methods 8021B/modified 8015, and for oxygenates MTBE, <br /> TBA, DIPE, ETBE, and TAME using EPA method 82606 <br />' Analytical results for the quarterly sampling event are presented in Table 1, and historical laboratory <br /> analytical results are summarized in Table 2 Highest dissolved benzene and TPH-G concentrations were <br />' reported in well MW-5A at 4,300 micrograms per liter(Ng/L) and 63,000 pg/L, respectively Elevated <br /> MTBE concentrations were detected in groundwater samples from wells MW4 and MW-5A at 4,100 Ng/L <br />' and 1,800 pg/L, respectively Dissolved benzene, TPH-G, and MTBE concentrations are plotted on <br /> Figure 2 The laboratory analytical reports are included in Attachment 4 <br /> Field records Indicate the presence of a possible offsite contaminant source, a remediation system was <br /> observed on the property located directly across North Pershing Avenue from the 7-Eleven site This <br /> finding may indicate plume mixing in the area of well MW4 with another hydrocarbon source (not 7- <br /> Eleven) Other quarterly data obtained during this sampling event are consistent with previous findings, <br /> indicating the hydrocarbon source is in the vicinity of the underground storage tanks Concentrations of <br /> benzene, TPH-G, and MTBE in the deeper nested well MW-513, are more than 99% lower than those <br /> observed in the shallow well MW-5A <br /> Prior to purging, dissolved oxygen (DO) levels were recorded in each well Dissolved oxygen levels <br />' ranged from about 0 4 milligrams per liter (mg/L) to 1 mg/L (Table 1) <br /> As mentioned m previous quarterly reports, a well search database for public water supply wells located <br /> within one mile of the site indicates that there are no public water supply wells located within 4,000 feet <br /> downgradient from the site The nearest crossgradient/upgradient water supply well of unreported status <br />' is located more than 1,500 feet southeast of the site <br /> 1 <br /> 17334Q11 QMR <br /> I <br />