Laserfiche WebLink
DAY RNIGHTr v V - CERTIFICATE V` NO, 29068 <br /> (510) 235-1393 CERTIFIED SERVICES COMPANY CUSTOMER <br /> 255 Parr Boulevard . Richmond, California 94801 <br /> JOB NO <br /> MANESS <br /> FOR ERICKSON,INC TANK NO, 2384I' <br /> LOCATION RICHMOND. CA DATE 9129/RB TIME 1 16'19 PM <br /> TEST METHOD <br /> VISUAL GASTI:CHA3114 SMPN EAST PRODUCT UG <br /> This is to certify that I have personalty determined that this tank is in accordance with the Amerlean <br /> Petroleum Institute and have found the condition to be Inrdance with Its assigned designation <br /> This certificate is based on conditions existing at the t�the Inspection herein set forth was <br /> completed and Is issued subject to compliance with all qualifications and Instructions <br /> , <br /> TANK SIZE io,000 GALLON TANK CONDITION SAFE FOR FIRE <br /> REMARKS OXYGEN 20.9%LMNER EXPLOS11JE LIM IT LESS THAN 0 1%ERICKSON, INC HERBY CERTIFIES THAT THE <br /> A13OVE NUMBERED TANK HAS BEEN CUT OPEN PROCI=wED,AND THEREFORE DESTROYED AT OUR <br /> PERrrA TTED HAZARDOUS WASTE FACILITY <br /> ,ANv <br /> In the event of any physical or atmospheric changes affecting the gas-free conditions of the above tanks, or if in any doubt, <br /> Immediately stop all hot work and contact the undersigned This permit is valid for 24 hours if no physical or atmospheric <br /> changes occur <br /> STANDARD SAFETY DESIGNATION <br /> SAFE FOR MEN Means that in the compartment or space so designated (a) The oxygen content of the atmosphere is at least <br /> 19 5 percent by volume, and that (b) Toxic materials In the atmosphere are within permissable concentrations, and (c) In the <br /> judgment of the Inspector, the residues are not capable of producing toxic materials under existing atmospheric conditions <br /> while maintained as directed on the Inspector's certificate <br /> SAFE FOR FIRE Means that in the compartment so designated (a) The concentration of flammable materials in the <br /> atmosphere Is below 10 percent of the lower explosive limit, and that (b) In the judgment of the Inspector, the residues are <br /> not capable of producing a higher concentration that permitted under existing atmospheric conditions In the presence of fire <br /> and while maintained as directed on the Inspector's certificate, and further, (c) A0 adjacent spaces have either been cleaned <br /> sufficiently to prevent the spread of fire, are satisfactorily inerted, or In the case of fuel tanks, have been treated as deemed <br /> necessary by the Inspector <br />�e undersign d representative acknowledges receipt of this certificate and understands t e ndltlone a 1i nations under <br /> nc <br /> ich it s i ued , <br /> e .R_ 1 r <br /> EP S NTATIYE TITLE IN TOR <br /> CPSB@6 <br />