Laserfiche WebLink
tech Analytical Labs,Inc. 525 Del Rey Avenue,Suite E <br /> Sunnyvale,CA 94086 <br /> QUALITY CONTROL RESULTS SUMMARY <br /> METHOD ICP <br /> QC Batch# SM980910 Date Analyzed 09/18/98 <br /> Matrix Solid Extraction Method EPA 3050 <br /> Ute Spiked Sample E 16083 <br /> ARAMETER Method# MB SA SR SP SP SPD SPD = RPD ` QC LMUTS <br /> = <br /> m9ft m m m %R =m %R RPD %R <br /> Antimony 6010 i <0 50 50 na i na na i na i na na i 250 63-112 <br /> !Arsenic 1 6010 ! <0 50 ! 50 I 102 1 49 [ 78 r 47 I 74 1 4.9 1 250 I 53-118 1 <br /> 1 1 ! I 1 I 1 ! ! ! I I ! <br /> :Barium : 6010 : <0 50 1 50 1 na ! na ! na ! na ! na : na I 250 1 57-120 1 <br /> :Beryllium 1 6010 1 <0 50 1 50 1 na 1 na 1 na r na ' na I na 1 250 1 64113 I <br /> I I 1 I I I I I I ! 1 r <br /> [Cadmium I 6010 I <0 50 + 50 1 na 1 na 1 na I na 1 na 1 na 1 250 1 68-104 1 <br /> 1 1 1 I I I 1 1 1 1 1 1 I <br /> :Chromium : 6010 1 <0 50 1 50 1 na 1 na : na 1 na : na : _ na 1 250 : 57-122 1 <br /> 1 <br /> Cobalt 1 6010 1 <0 50 1 50 1 na 1 na 1 na I na ! na 1 na 1 250 1 59-113 1 <br /> F I I I F 1 1 1 1 I I 1 <br /> [Copper 1 6010 I <0 50 1 50 1 na [ na 1 na 1 na 1 na 1 ria ! 25 0 1 49-130 ! <br /> I I I 1 I I I I I I 1 1 I <br /> Iliad 1 6010 I <0 50 1 50 10 0 I 50 I 99 I 46 1 92 I 79 1 250 ! 59-112 I <br /> 1 1 ! 1 E I 1 ! 1 ! 1 ! I <br /> :Molybdenum s 6010 s <0 50 1 50 s ria s ria ! ria s ria s ria ! ria 1 250 s 4$-117 1 <br /> :Nickel 1 6010 1 <0 50 1 50 I na 1 na 1 na 1 na ! na 1 na 1 250 1 51-126 1 <br /> 1 I 1 I I 1 I r r I I ! <br /> tSelenium 1 6010 1 <0 50 1 50 1 na 1 na 1 na I na 1 na 1 na 1 250 1 50-115 1 <br /> t I I ! I I I I I I ! I I <br /> r"""' 1 6010 1 <0 50 1 50 ! na 1 na s na s na 1 na 1 na ! 250 1 56-115 1 <br /> um I 6010 1 <0 50 1 50 I na 1 na 1 na I na 1 na 1 na 1 250 1 57-116 1 <br /> ! 1 I 1 ! 1 1 I 1 I 1 I <br /> Wanadtum 1 6010 1 <0 50 1 50 1 na i na 1 na 1 na 1 na I na 1 250 1 51-129 1 <br /> :Zinc na! 6010 I <0 50 1 50 1 1 1 I I I 1 I 1 <br /> : 1 : 1 1 1 ria 1 ria I ria 1 ria I ria : 250 l 60-118 1 <br /> 1 1 1 I 1 I i I 1 1 1 I 1 <br /> Note LCS and LUND results reported for the following Parameters <br /> Lead <br /> .Acceptable LCS and LCSD results are reported when matrix interferences cause Aa and MSD results to fall outside <br /> established QC limits <br /> Definition of Terms <br /> na. Not Analyzed in QC batch <br /> MB Method Blank <br /> SA Spike Added <br /> SR. Sample Result <br /> SP Spike Result <br /> SP(%R) Spike%Recovery <br /> SPD Spike Duplicate Result <br /> SPD(%R) Spike Duplicate%Recovery <br />