Laserfiche WebLink
Entcch Analytical Labs,Inc, 525 Del Rey Avenue,Suite E <br /> Sunnyvale,CA 94086 <br /> QUALITY CONTROL RESULTS SUMMARY <br /> METHOD ICP <br /> QC Batch# SM980910 Date Analyzed 09/18/98 <br /> Matrix Solid Exbwhon Method EPA 3050 <br /> Units MAU S :ked Sample E16083 <br /> FARAMETER Method# MB SA SR SP SP SPD SPD RPD <br /> QC L1IVIITS <br /> mg& m mgtkg m %.R ,m %R RPD %R <br /> :Antimony 6010 : <0 50 50 : na : na : na : na na na 250 : 63-112 : <br /> IAtsemc 1 6010 1 <0 50 1 50 1 102 1 49 1 78 1 47 1 74 1 49 1 250 1 53-118 I <br /> Banum i 6010 i <0 50 i 50 i na i na i na i na i na i na i 250 i 57-120 : <br /> 1 <br /> :Beryllium ' 6010 ' <0 50 ' 50 ' na ' na : na : na } na : na ' 250 ' 64-113 ' <br /> I I 1 I I r 1 1 I I F I I <br /> 'Cadmium 1 6010 1 <0 50 1 50 1 na I na I na 1 na I na I na I 250 1 68-104 1 <br /> I I I 1 I I I I I I f i <br /> :Chromium 1 6010 1 <0 50 I 50 i} na I na 1 na i na f na 1 - na 1 250 1 57-122 i <br /> :Cobalt ' 6010 ' <0 50 : 50 ' na ' na ' na : na : na ' na ' 250 ' 59-113 ' <br /> 1 I 1 I I 1 ! 1 I I 1 1 I <br /> :Copper 1 6010 : <0 50 : 50 1 na : na 1 na : na : na : na 1 250 : 49-130 1 <br /> I 1 I I 1 I I I I I I I <br /> (Lead I 6010 1 <0 50 } 50 10 0 1 50 1 99 I 46 1 92 1 79 I 250 1 59-112 1 <br /> :Molybdenum : 6010 ' <0 50 ' 50 ' na na: : na : na ' na ' na : 250 : 48-117 : <br /> I I I I I t 1 1 I I F ! 1 <br /> :Nickel : 6010 <0 50 : 50 : na t na : na : na : na : na : 250 : 52-126 : <br /> 1 I r I I I I I I I I I I <br /> ISelemurn 1 6010 1 <0 50 1 50 t na 1 na I na 1 na I na I na 1 250 1 50-115 I <br /> I 1 I 1 ! I I 1 1 I 1 1 I <br /> ,10gilver } 6010 1 <0 50 50 1 na 1 na F na na 1 na i na 250 1 56-115 1 <br /> lFhalhum 1 6010 : <0 50 ' 50 ' na : na : na : na ' na : na ' 250 ' 57-116 : <br /> (Vanadium 1 6010 1 <0 50 1 50 1 na 1 na 1 na 1 na i na t ria 1 250 1 51-129 1 <br /> :Zino : 6010 I <0 50 : 50 : na : ' <br /> I 1 I 1 I i na 1 na I ria 1 na 1 na 1 250 1 60-117 � <br /> 1 I 1 I I 1 I I I I I F I <br /> Note LCS and LCSD results reported for the following Parameters <br /> Lead <br /> Acceptable LCS and LCSD results are reported when matrix interferences cause MS and MSD results to fall outside <br /> established QC limits <br /> Definition of Terms <br /> na Not Analyzed in QC batch <br /> MB Method Blank <br /> SA Spike Added <br /> SR Sample Result <br /> SP Spike Result <br /> SP(%R) Spike%Recovery <br /> SPD Spike Duplicate Result <br /> SPD(%R) Spike Duplicate%Recovery <br /> 0 <br />