My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0009097
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PERSHING
>
4555
>
3500 - Local Oversight Program
>
PR0545652
>
ARCHIVED REPORTS_XR0009097
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/6/2020 3:47:14 PM
Creation date
5/6/2020 3:31:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0009097
RECORD_ID
PR0545652
PE
3528
FACILITY_ID
FA0003638
FACILITY_NAME
JEMCO VENETIAN CARDLOCK
STREET_NUMBER
4555
Direction
N
STREET_NAME
PERSHING
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
11017001
CURRENT_STATUS
02
SITE_LOCATION
4555 N PERSHING AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� w <br /> CLEARWATER GROUP,INC <br /> Groundwater Monitoring and Sampinng Protocols <br /> w <br /> Prior to beguuungg,a decontamination area is established Decontamination procedures consist of scrubbing downhole <br /> equipment in an Alconox®solution wash(wash solution is pumped through any pur�ung pumps used),and rinsing in a <br /> first rinse of potable water and a second rinse of potable water or deioruzed water if the latter is required Any non- <br /> dedicated down hole equipment is decontaminated prior to use <br /> Prior to purging and sampling a well,the static water level is measured to the nearest 0 01 feet with an electroruc <br /> water sounder Depth to bottom is typically measured once per year,at the request of the project manager,and during <br /> Clearwater s first visit to a site If lustoncal analytical data are not available, with which to establish a reliable <br /> order of increasing well contamination, the water sounder and tape will be decontaminated between each well If <br /> floating separate-phase hydrocarbons (SPH) are suspected or observed,SPH is collected using a clear, open-ended <br /> product bailer,and the thickness is measured to the nearest 0 01 feet in the bailer SPH may alternatively be measured <br /> with an electronic interface probe Any morutonn�well containing a measurable thickness of SPH before or during <br /> purging is not additionally purged and no sample is collected from that well Wells containing a hydrocarbon sheen <br /> are sampled unless otherwise specified by the project manager Field observations such as well untegnty as well as <br /> water level measurements and floating product thicknesses are noted on the Gauging Data/Purge Calculations form <br /> Well PurgIn <br /> Each monitoring well to be sampled is purged using either a PVC bailer or a submersible pump Physical parameters <br /> (pH,temperature and conductivity)of the purge water are monitored dunng purging activities to assess if the water <br /> sample collected is representative of the aquifer If required,parameters such as dissolved oxygen,turbidity,salinity <br /> etc are also measured Samples are considered representative if parameter stability is achieved Stability is defined as <br /> a change of less than 0 25 pH units, less than 10/o change in conductivity in micro mhos, and less than 10 degree <br /> centigrade(1 8 degrees Fahrenheit)change in temperature Parameters are measured in a discreet sample decanted from <br /> the bailer separately from the rest of the purge water Parameters are measured at least four mines dun ng purging, <br /> initially, and at volume intervals of one well volume Purging continues until three well casing volumes have been <br /> removed or until the well completely dewaters Wells which dewater or demonstrate a slow recharge,may be sampled <br /> after fewer than three well volumes have been removed Well purging information is recorded on the Purge Data sheet <br /> All meters used to measure parameters are calibrated daily Purge water is sealed, labeled, and stored on site in <br /> D O T-approved 55-gallon drums After being cheuucally profiled,the water is removed to an appropriate disposal <br /> facility by a licensed waste hauler <br /> Groundwi5tCL5_3MaPkCoJlect3on <br /> Groundwater samples are collected immediately after purging or,if purging rate exceeds well recharge rate,when the <br /> well has recharged to at least 80% of its static water level If recharge is extremely slow, the well is allowed to <br /> recharge for at least two hours,if practicable, or until sufficient volume has accumulated for sampling The well is <br /> sampled within 24 hours of purging or repurged Samples are collected using polyethylene bailers,either disposable or <br /> dedicated to the well Samples being analyzed for compounds most sensitive to volatilization are collected first <br /> E <br /> Water samples are placed in apgro nate laboratory-supplied containers,labeled,documented on a chain of custody <br /> form and placed on ice in a cooler or transport to a state-certified analytical laboratory Analytical detection limits <br /> match or surpass standards required by relevant local or regional guidelines <br /> Qladlity1&5ULince Procedures <br /> To prevent contamination of the samples,CGI personnel adhere to the following procedures in the field <br /> • A new,clean pair of latex gloves are put on prior to sampling each well <br /> Wells are gauged,purged and groundwater samples are collected in the expected order of increasing degree of <br /> contamination based on historical analytical results <br /> • All purging equipment will be thoroughly decontaminated between each well, using the procedures previously <br /> described at the beginning of this section <br /> During sample collection for volatile organic analysis,the amount of air passin through the sample is minimized <br /> This helps prevent the air from stnpping the volatiles from the water Sample bottles are filled by slowly running <br /> the sample down the side of the bottle until there is a convex meniscus over the mouth of the bottle The lid is <br /> carefully screwed onto the bottle such that no air bubbles are present within the bottle If a bubble is present,the <br /> cap is removed and additional water is added to the sample container After resealing the sample container, if <br /> bubbles still are present inside, the sample container is discarded and the procedure is repeated with a new <br /> container <br /> s <br /> CLEARWATER GROUP,INC 1 October 8, 1996 <br />
The URL can be used to link to this page
Your browser does not support the video tag.