Laserfiche WebLink
Groundwater samples were collected from the five monitor wells on November 19, 1992 and <br /> submitted for laboratory analysis The analytical results indicated that no detectable <br /> concentrations of TPH were present in the groundwater samples collected from the five monitor <br /> wells at the site Concentrations of benzene were detected in groundwater samples collected <br /> from monitor wells MW2, MW3 and MW4 at 0.58 micrograms per liter (µg11), 7 7 µg/1 and <br /> 18 µg11, respectively Toluene and ethylbenzene were detected only in the groundwater sample <br /> collected from well MW4 at a concentration of 1.2 µg/l, respectively Xylenes were detected <br /> in groundwater samples collected from MW3 and MW4 at concentrations of 1 2 µg11 and 13 5 <br /> µg11, respectively <br /> Groundwater samples were collected from the five monitor wells on June 4, 1993 and submitted <br /> for laboratory analysis The analytical results indicated that detectable concentrations of TPH <br /> as gasoline were present in the groundwater samples collected from monitor well MW 1 and <br /> MW4 at concentrations of 0 69 All and 0 84 µll, respectively Concentrations of benzene were <br /> detected in groundwater samples collected from monitor wells MW2, MW3 and MW4 at <br /> concentrations of 9 5 All, 78 All and 430 All, respectively Toluene and ethylbenzene were <br />! detected in groundwater sample collected from MW 1 at 6.0 All and 1 1 All, respectively, and <br /> ethylbenzene was detected in MW2 and MW4 at concentrations of 0 92 All and 20 µl1, <br /> respectively Xylenes were detected in groundwater samples collected from MWl, MW2 and <br /> MW4 at concentrations of 1 1 All, 6 9 All and 91 All, respectively. <br /> This report presents the results of the September 1993 quarterly groundwater monitoring event <br /> conducted at the property, the second groundwater sampling event performed at the property <br /> This work was conducted in accordance with the State Water Resources Control Board Leaking <br /> Underground Fuel Tank (LUFT) and Regional Water Quality Control Board (RWQCB) <br /> guidelines for the preliminary evaluation and investigation of underground tank sites <br /> Groundwater samples were not collected following the November 1992 sampling event until June <br /> 1993 Quarterly sampling has continued at three month intervals (i e , September, December) <br /> since June 1993 <br /> 2.0 WATER LEVEL MEASUREMENTS <br /> Water surface elevation data were obtained from the monitoring wells at the subject site on <br /> September 3, 1993 Water surface elevation data are presented in Table 1 Contours of equal <br /> water surface elevation developed from the data are presented in the Potentiometnc Surface Map <br /> included as Figure 2 Sample event data sheets are included as Appendix I <br /> Groundwater elevations measured September 3, 1993 were approximately three to five tenths <br /> of a foot lower than when last measured on June 4, 1993 Groundwater at the site on <br /> September 3, 1993 was determined to flow to the northeast <br /> 09201cd1 3 <br />