My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0009380
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PERSHING
>
5608
>
3500 - Local Oversight Program
>
PR0545653
>
ARCHIVED REPORTS_XR0009380
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/6/2020 4:27:37 PM
Creation date
5/6/2020 4:04:49 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0009380
RECORD_ID
PR0545653
PE
3528
FACILITY_ID
FA0003727
FACILITY_NAME
CHEVRON STATION #96465 (INACT)
STREET_NUMBER
5608
Direction
N
STREET_NAME
PERSHING
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
10815011
CURRENT_STATUS
02
SITE_LOCATION
5608 N PERSHING AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GROUNDWATER TECHNOLOGY GROUNDWATER MONITORING AND SAMPLE <br /> COLLECTION PROTOCOL <br /> Groundwater Monitoring <br /> Groundwater monitoring is accomplished using a INTERFACE PROB5" Well Monitoring System. The <br /> INTERFACE PROBE" Well Monitoring System is a band held. battery operated device for measuring the <br /> depth to separate-prase hydrocarbons and depth to water. The INTERFACE PROBE" Well Monitoring <br /> System consists of a dual-sensing probe which utilizes an optical liquid sensor and electrical <br /> conductivity to distinguish between water and petroleum products. <br /> Monitoring is accomplished by measuring from the surveyed top of well casing or grade to groundwater <br /> and separate-phase hydrocarbons If present. The static water elevation Is then calculated for each well <br /> and a potentiometric surface map is constructed if separate-phase hydrocarbons are detected the <br /> water elevation is adjusted by the following calculation: <br /> (Product thickness) x (0 8) + (Water elevation) = Corrected water elevation <br /> Groundwater monitoring wells are monitored in order of wells with lowest concentrations of volatile <br /> organic compounds to wells with the highest concentrations, based upon historical concentrations. If <br /> separate-phase hydrocarbons are encountered In a well,the product is visually Inspected to confirm and <br /> note color, amount. and viscosity. Monitoring equipment is washed with laboratory grade detergent and <br /> rinsed with distilled or deionized water before monitoring each well. <br /> Groundwater Sampling <br /> Before groundwater samples are collected, sufficient water is purged from each well to ensure <br /> representative formation water Is entering the well. Wells are purged and sampled in the same order as <br /> monitoring, from wells with the lowest concentrations of volatile organic compounds to wells with the <br /> highest concentrations Wells are purged using either a polyvinyl chlonde (PVC) bailer fitted with a <br /> check valve or with a stainless steel submersible Grundfos pump. The purge equipment Is <br /> decontaminated before use in each well by washing with laboratory grade detergent and tripled rinsing <br /> with delonized or distilled water. A minimum of 3 well-casing volumes of water are removed from each <br /> well while pH, electrical conductivity, and temperature are recorded to verify that "fresh"formation water <br /> Is being sampled and the parameters have stabilized. If the well Is low yielding, It may be purged dry <br /> and sampled before 3 casing volumes are purged. The wells are then allowed to recharge to <br /> approximately 80 percent of the initial water level before a sample Is collected. <br /> Groundwater samples are collected from each well using a new, prepackaged disposable bailer and <br /> string. The water sample is decanted from the bailer into laboratory-provided containers (appropriate for <br /> the analyses required) so that there is no headspace In the oontainers. Samples collected for benzene, <br /> toluene, ethylbenzene, xylene, and total petroleum hydrocarbons (TPH)-as-gasoline analyses are <br /> collected in 40-mililliter vials fitted with Teflon® septum lids. Samples are preserved with hydrochloric <br /> acid (HCL) to a pH of less than 2 Dissolved metals samples are filtered through a 0 45-micron paper <br /> filter in the field and preserved as required before submitting to the laboratory for analyses All samples <br /> are labeled Immediately upon collection and logged on the chain-of-custody record Sample label and <br /> chain-of-custody recorded Information includes the project name and number, sample Identification,date <br /> and time of collection, analyses requested, and the samplers name. Sample bottles are placed in <br /> plastic bags (to protect the bottles and labels) and on Ice (frozen water) In an Insulated cooler and are <br /> shipped under chain-of-custody protocol to the laboratory. <br /> The chain-of-custody record documents who has possession of the samples until the analyses Is <br /> performed Other pertinent information Is also noted for the laboratory use on the chain-of-custody <br /> record <br /> Trip blanks (TBLBs) are used for each project as a quality assurance/quality control measure The <br /> TB!_Bs are prepared by the laboratory and are placed in the Insulated cooler and accompany the field <br /> samples throughout the sampling event <br />