Laserfiche WebLink
-Nov-13-2002 11:2Tam Frcm-ARCO PRODUCTS +714-670-3095 T-817 P 005/007 F-536 <br /> raIIIIIV1) PR(1(.RAM Cf1\r',CC1T.TnATF.1) VO ---- <br /> TANKS <br /> UNDERGROUND STORAGE TANKS- TANK PAGE 2 <br /> VI.PIPIN 'CONSTRUCTIONICT>ca14n rhat.pplyl Pae of <br /> LINDERGROLND PIPING ABOVEGROLND Pp1p1NG <br /> SYSTEM 1TYrk ®1.PRESS1,II2F, ©2 SUCTION ❑3.GRAVI'T'Y =38 Q 1.PRESSURE ❑ SUCTION Q GRAVITY 4sa <br /> CONSTR N/ ©1.SLN'GLE WALL 0 3,LINED TRENCH ❑99.OTH1iR ase Q 1.SINGLE WALL <br /> MANUF4,C URER Q 95.UNKNOWN 462. <br /> ®2.DOUBLE WALL 1195,UNKNOWN Q 2.DOUBLE WALL <br /> ❑99,OTHER <br /> MANUFACTURER �! MANUFACT CJW-a 469. <br /> ❑1.BARE STEEL ❑6.FRP COMPATIBLE w/1DO`%METHANOL ❑ 1.BARE,STEEL ❑6,FRP C0.'1y>ATIBLE W.'IOD%WTHANOL <br /> ❑2,STAINLESS STEEL Q 7.GALVAN1220 STEEL ❑2 STAINLESS STED ❑7.GALVANIZED STEEL <br /> Iv 3.PLASTIC COMPATIBLE WITH CONTENTS [3 95.UNKNOWN Q 3.PLASTIC COLOA'I IBLE W1 CONTENTS ❑8,FLEXIBLE(HDPE) ❑99.OTHER <br /> 4.FIBERGLASS ❑6.FLEXIBL]?RIDPE) D 99,OTHEF ❑4.FIBERGLASS <br /> ❑9.CATHODIC PROTEC'T'ION <br /> ❑5 STEEL 1V/COATING ❑9.CATHODIC PROTECT/ON 464 i'Q 5 STEEL W/COATTD••i ❑95.UNKNOWN 465 , <br /> VII.PIP NIC:LEAKDEI'IFCj'lON Cho&all iha IAdevarinion offs ma,iwrv, rn m:halt boaseoronOu to tFa,bcel. y <br /> UNDERGROUND P1P1`dG ABOVEGROUIVDPIPL14G <br /> SINGLE WALL PIPING 46e SINGLE WALL PIPING 46; <br /> PR£Sb�URILED PIPJNG(Check ill that app',y): I PRESSURIZI n PIPING(Check at:that apply): <br /> fl C3 <br /> I. ELECTRONIC LINLEAK AK DETECTOR 3.0 OPH TEST WITH AUTO PUMP ❑t. ELECT,cON1C LINE LEAK DFTECTOR 3 0 GPH TEST WIT14 AUTO PUMP I <br /> SHUT-OFF FOR LEAK,SYSTEM FATLVU1 .AND SYSTEM DISCONNECMN SFIU'T I AFF FOR LEAK,SYSTEM FA'LURE,AND SYSTEM DISCONNECTION III <br /> AUDIBLE AND VISUAL ALARMS -AUDIBLE AND'Vt$UAL ALARMS, <br /> [12. MON'T'HLY 0.2 GPH TEST 02 MONTI ILY 0.2 GPH TEST <br /> ❑3. ANNUAL INTEGRITY TEST(0,1 GPII) 0 3, ANNUdl INfBGRITY'TEST(0 t GPH) <br /> 04. DAILY VISUALCHLCK <br /> CONVENTIONAL SUCTION SYSTEMS CONVENTIOYAL!SUCTION SYSTEMS(Chcok 4it that apply) <br /> ❑5. DAII.Y VISUAL MONTTORING OF'PUMPING SYSTEM•,TRI%NNIAL PIPING <br /> INTEGRITY TEST(0,1 GPM) ❑S DAILY VISUAL MONITORING OF PIPINt3 AND Pall 1NG SYSTEM <br /> SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING)! ❑6- TRIENI,IAL INTrGRITY TEST(O.l GPH) f! <br /> ❑7. SELF MONITORING SAFE SUCTI(In SYSTEMS(NO VALVES IN BELOW GROUND PIPING): <br /> GRAVITY FLOW I ❑7. SELF MONITORING <br /> 119, BIENNIAL INTEGRITY TES-l-,0,1 GPH) GRAVITY FL+IW tChack all that apply): <br /> I ❑Il. DAILY tfSUAL MGNI7.ORING <br /> ❑9. BIENNI,,L LVTEGRl7y TEST(o.l GPH) <br /> ! SECONDARIILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPINC(Check all Otar appl ): PRESSURIZEI r PIPING(Check all that apply): <br /> 10, CONTINUOUS TURBINE SUMP SENSOR Wrrt4 AUDIBLE AND VISUALi 10, CONTINUOUS TUR2TNl SUMP SENSOR WITH AL7S!13LE AND vISL'AL <br /> ALARMS AND(Check one) I ALARA:3 ANIS(Check one) <br /> [3a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS Ma.Al'TO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> ®b.AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM ❑b.Ai ITO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM <br /> DISCONNECTION Di WONNECTION <br /> i]e. NO AUTO PLW SHUT OFF Inc NI-AUTO A;MP SHUT OFF <br /> IM 11, AUTOMATIC LINE LCAT,DETECTOR(3.0 OPII TEST)W(TH FLOW SHUT <br /> OFF OR RESTRICTION ❑11. AUTON 1TIC LEAK DETECTOR <br /> ❑12. ANNUAL INTEGRITY TEST(0.1 GPH) C]17 ANNUA,.INTEGRITY TEST(0.1 GPH) <br /> SU'CTIONIGRAVITY SYSTEM SUCTLONIGRA CITY SYSTEM <br /> ❑13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS ❑13,CONTBNJOUS SI-IMP SENSOR,AUDIBLE AND VISUAL ALAR-mS <br /> EMERGENCY GENERATORS ONLY(Check all that apply) EMERGENCY GENKRATORS ONLY(Check ell:(tat apply) <br /> ❑14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SI•IUT OFF ❑ 14.CONTI NOUS SUMP SENSOR-V TI{C.UT AUTO PLINe SHUT OFF <br /> AUDIBLE AND VISUAL ALARMS AUDIB:.E AND VISUAL ALARMS <br /> ❑15. AUTOMATIC LINE LEAK DETECTOR (3.0 GPH TEST) wmwntiT FLOW <br /> SHUT OFF OR RESTRICTION ❑I5 AUTOl.tATtTF <br /> 1CI.INELEAKnCTGR(3.OGPFITEST) <br /> 016. ANNUAL INTEGRITY TEST(0.1 GPH) 0 16.ANNUL INTE6RITYTEST(0,!OPFl) <br /> ❑11. DAILY VISUAL CHECK M 17, DAILY VISUAL CHECK <br /> VIJI.J]ISP.ENSER CONTAININILNT <br /> DISPENSER CONTAINMENT aha. 1 ❑I. FLOAT MECHANISM THAT SHUTS OFF S14EAR VALA,i ❑4, DAILY VISUAL CIMCK 469 <br /> DATE INSTALLED IM2. CONTINUO*!SDISPL•NSERPAN$_NSOR-ALJDEBLE,\NDVIS(IALALAnIS ❑s. TRENCH/LINERiv10NITORINO <br /> 1071999 ❑1 CONTINUOUS DISPENSER PAN SENSOR W1TTi ,x,)'1'0 SHUT OFF FOR ❑6 NONE <br /> __111 DISPENSER T AUDIAL2 AND VISUAL,ALARIvfS <br /> AC.OWNEWOPERATOR SI(;NATI IRE <br /> I certif that the information provided bewin is true and accurate to the best of my knowledge. ��- <br /> SIGN v 0 R A I 0XII DATE: <br /> NA]2 O 4PERATOR(print): JOHN SCHETrER TITLE OF OWN`!R/OPERATOR: EnVifOnmental Compliance 01 <br /> Permit Number(Agency ttaa Only) Ova 1 Permit Approved My(Agency asa only) 474. Pau,t Expiration Date(.4E•en;:y use only) a7I. <br /> UPCF hwllvre-b(1/9'1)-3/4 tlt4p:/hvww.unidamorg Rev,0:116/00 <br />