Laserfiche WebLink
UNIFIED PROGRAM CONSOLIDATED rORM t <br /> TANKS <br /> UNDERGROUND STORAGE TANKS -TANK PAGE 2 <br /> VI,PIPING CONSTRUCTION(Check allthat appy) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SYSTEM TYPE 1 PRESSURE ❑ 2. SUCTION ❑ 3. GRAVITY ❑ 1. PRESSURE ❑ 2. SUCTION ❑ 3. GRAVITY <br /> CONSTRUCTION/ ❑ 1. SINGLE WALL ❑ 3. LINED TRENCH ❑99. OTHER ❑ 1. SINGLE WALL El95. UNKNOWN <br /> MANUFACTURER 2. DOUBVEWALL ❑95. UNKNOWN 112. DOUBLE WALL El 99. OTHER <br /> MANUFACTURER MANUFACTURER <br /> ❑ 1.BARE STEEL 6. FRP COMPATIBLE W/100%METHANOL ❑ 1. BARE STEEL ❑ 6. FRP COMPATIBLE W/100%METHANOL <br /> MATERIALS AND ❑ 2, STAINLESS STEEL ❑ 7. GALVANIZED STEEL ❑ 2. STAINLESS STEEL ❑ 7. GALVANIZED STEEL <br /> CORROSION <br /> PROTECTION ❑ 3. PLASTIC COMPATIBLE WITH CONTENTS 1195. UNKNOWN ❑ 3. PLASTIC COMPATIBLE WITH CONTENTS ❑ 6. FLEXIBLE(HDPE) ❑99. OTHER <br /> ❑ 4. FIBERGLASS ❑ B. FLEXIBLE(HDPE) ❑99. OTHER ❑ 4 FIBERGLASS ❑ B. CATHODIC PROYECTIQN' <br /> ❑ 5. STEEL W/COATING ❑ 9. CATHODIC PROTECTION ❑ 5. STEEL W/COATING ❑95. UNKNOWN <br /> VII.PIPING LEAK DETECTION(Check alf that apply) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING SINGLE WALL PIPING <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> Is 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPM TEST WITH AUTO PUMP SHUT OFF FOR ❑ 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPM TEST WITH AUTO PUMP SHUT OFF FOR LEAK, <br /> LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION r AUDIBLE AND VISUAL SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND VISUAL ALARMS <br /> ALARMS ❑ 2. MONTHLY 0.2 GPM TEST - <br /> ❑ 2. MONTHLY 0.2 GPM TEST ❑ 3. ANNUAL INTEGRITY TEST(0.1 GPM) <br /> ❑ 3. ANNUAL INTEGRITY TEST(0.1 GPM) ❑ 4, DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS: CONVENTIONAL SUCTION SYSTEMS(Check all that apply): <br /> ❑ 5. DAILY VISUAL MONITORING OF PUMPING SYSTEM.TRIENNIAL PIPING INTEGRITY ❑ 5. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> TEST(0.1 GPM) ❑ 6. TRIENNIAL INTEGRITY TEST(0.1 GPM) <br /> SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): <br /> ❑ 7. SELF MONITORING ❑ 7. SELF MONITORING <br /> GRAVITY F LOW: GRAVITY FLOW(Check all that apply): <br /> ❑ 9. BIENNIAL INTEGRITY TEST(0.1 GPM) ❑ B. DAILY VISUAL MONITORING <br /> ❑ 9. BIENNIAL INTEGRITY TEST(0.1 GPM) <br /> SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> 0 CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND 10.CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND(check one) <br /> (Check one) <br /> a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS ❑ a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> ❑ b. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM ❑ b. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM DISCONNECTION <br /> DISCONNECTION <br /> ❑ c. NO AUTO PUMP SHUT OFF ❑ c. NO AUTO PUMP SHUT OFF <br /> ❑ 11. AUTOMATIC LINE LEAK DETECTOR(3.0 GPM TEST)WITH FLOW SHUT OFF OR ❑ 11. AUTOMATIC LEAK DETECTOR <br /> RESTRICTION <br /> ❑ 12. ANNUAL INTEGRITY TEST(0.1 GPM) ❑ 12.ANNUAL INTEGRITY TEST(0.1 GPM) <br /> SUCTION/GRAVITY SYSTEM: SUCTION/GRAVITY SYSTEM: <br /> ❑ 13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS ❑ 13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(Check all that apply) EMERGENCY GENERATORS ONLY(Check all that apply) <br /> ❑ 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF+AUDIBLE AND ❑ 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF+AUDIBLE AND VISUAL <br /> VISUAL ALARMS ALARMS <br /> ❑ 15. AUTOMATIC LINE LEAK DETECTOR(3.0 GPM TEST)WITHOUT FLOW SHUT OFF OR ❑ 15. AUTOMATIC LINE LEAK DETECTOR(3.0 GPM TEST) <br /> RESTRICTION <br /> ❑ 16. ANNUAL INTEGRITY TEST(0.1 GPM) ❑ 16. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑ 17. DAILY VISUAL CHECK ❑ 17. DAILY VISUAL CHECK <br /> VIII.DISPENSER CONTAINMENT <br /> DISPENSER CONTAINMENTT[1 1. FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE ❑ 4. DAILY VISUAL CHECK <br /> DATE INSTALLED 2. CONTINUOUS DISPENSER PAN SENSOR+AUDIBLE AND VISUAL ALARMS ❑ 5. TRENCH LINER/MONITORING <br /> ❑ 3. CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR DISPENSER+AUDIBLE AND VISUAL ALARMS ❑ 6. NONE <br /> IX.OWNER)OPERATOR SIGNATURE <br /> I certify that the omtalion vided h in is true and accurate to the best of my knowledge. <br /> SIGNA 0 OWNE PERATIM <br /> DATE <br /> NAMEER ATOR�phnO,F�^J TITLE OF OVVNER/OP�RATO <br /> Permit Number(Fo0ocal use only)5, Permit Approved(For local use only) Permit Expiration Date(For local use only) <br /> CUPAFORM(4/99) Formerly SWRCB Form B <br />