Laserfiche WebLink
UNIFIED PROGRAM CONSOLIDATED FORM <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN - (Page 1 of 3) <br /> TYPE OF ACTION ❑ 1.NEW PLAN ® 2.CHANGE OF INFORMATION 490-1 <br /> PLAN TYPE ® 1 MONITORING IS IDENTICAL FOR Al.I USTs AT THIS FACII ITY T90-2- <br /> (Check one item only) ❑ 2 IHIS PIAN COVERS ONLY THE FOLLOWING(IST SYSIEM(S): 490-2° <br /> I. FACILITY INFORMATION <br /> FACILITY ID#(Agency Use Only) I <br /> I <br /> BUSINESS NAME(Same as Facility Name or DBA) ARCO 06080 4 <br /> BUSINESS SITE ADDRESS 85 E LOUISE AVENUE 103 BUSINESSSITECITY LATHROP 1w <br /> II. EQUIPMENT TESTING AND PREVENTIVE MAINTENANCE <br /> Testing,preventive maintenance,and calibration of monitoring equipment(e g,sensors,probes,line leak detectors,etc)must be performed at the frequency specified <br /> bkthe a uq ipment manufacturers'instructions,or annually,whichever is more frequent.Such work must be perforrnedy qualified personnel.123 CCL§z63z,2634_26382W Il- <br /> 490-30- <br /> MONITORING EQUIPMENT IS SERVICED ® 1.ANNUALLY ❑ 99.OTHER(Specify): 490-3b. <br /> III. MONITORING LOCATIONS <br /> ® I.NEW SITE PLOT PLAN/MAP SUBMITTED WITH THIS PLAN ❑ 2.SITE PLOT PI,AN/MAP PREVIOUSLY SUB`4ITTED [23 CCR§2632.26341 4904 <br /> IV. TANK MONITORING IS PERFORATED USING THE FOLLOWING METHOD(S) jJoi`ckappJA <br /> I CONTINUOUS ELECTRONIC TANK MONITORING OF ANNULAR(INTERSTITIAL)SPACE(S)OR SECONDARY CONTAINMENT VAUL.T(S) 490-5 <br /> WITH AUDIBLE AND VISUAL ALARMS [23 CCR§2632 26341 <br /> SECONDARY CON IAINMENI IS ❑ a DRY ® b 1.IQUTD FILLED ❑ c PRESSURIZED ❑ d UNDER VACUUM 490.6 <br /> PANEL MANUFACTURER: Veeder Root 490-7 MODEL#: TLS-350 4901$ <br /> LEAK SENSOR MANUFACIL'R-ER: Veeder Root 490.9 MODEL#(S): 794380-3 490-10 <br /> ❑ 2 AUTOMATIC TANK GAUGING(ATG)SYSTEM CSED TO MONITOR SINGLE WALL TANKS) [23 CCL§264-31 490-11 <br /> PANEL MANUFACTURER: 49112 MODEL#: 490.13 <br /> IN-IANK PROBE MANUFACTURER: 490.14 MODEL#(S): 490-15 <br /> LEAK]EST FREQUENCY: ❑ a CONTINUOUS ❑ b DAIL Y/NIGH I L Y ❑ c WEEKLY 490-16 <br /> ❑ d MONTHLY ❑ e OIHER(Specify): 490.17 <br /> PROGRAMMED IESTS: ❑ a.0.1 h b.0.2 h. ❑ c.OTHER(Specify): 490-I8 <br /> ___.--_--�-P � 8P ( P fY)�. --490-19 _ <br /> ❑ 3.MONTHLY STATISTICAL.INVENTORY RECONCILIATION[23 CCR§2646.11 490-20 <br /> ❑ 4.WEEKLY MANUAL TANK GAUGING(MTG)123 CCR§26451 ]ESTING PERIOD: [Ia.36 HOURS Elb 60 HOURS 4 <br /> 490-2z.22. <br /> ❑ 5 TANK INTEGRITY TESTING PER[23 CCR§264311 490-23 <br /> IESI FREQUENCY: [I a ANNUALLY Elb.BIENNIALLY El c. 490-24 <br /> OTHER(Specify)` .__...__� 490.25. <br /> ❑ <br /> 99.OTHER(Specify): - 49 <br /> 490-27., <br /> V. PIPE MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S) �jec*a" <br /> ® 1.CONTINUOUS MONITORING OF PIPEMIPING SUMP(S)AND 0.1 HER SECONDARY CON-I AINMENf WITH AUDIBLE&VISUAL ALARMS 490-28 <br /> [23 CCR SECONDARY CON IANMENI IS: M a DRY [Ib LIQUIDFILLED ❑ c.PRESSURIZED El UNDERVACUUM 490-29 <br /> §2636PANEL MANUFACTURER:Veede!Root 490-30 MODEL#: TLS-350 490-31 <br /> LEAK SENSOR MANUFACTURER: Veeder Root 490.32 MODEL#(S): 794380-323 490.33 <br /> PIPING LEAK ALARM IRIGGERS AUTOMATIC PUMP(i e,TURBINE)SHUTDOWN ® a YES ❑ b NO 490.34 <br /> FAILURE/DISCONNECIION OF IHE MONITORING SYSTEM IRIGGERS AUTOMATIC PUMP SHUI DOWN. ® a YES [Ib.NO 490-35 <br /> -.._.____...... _-.__._..._..._-._._.___.._..---.--._........._...._..-----.---------.---_._..._.._._...__ <br /> 1,6_9 ph <br /> .._..___......____.__......__..__..._-..__.._.._____..... <br /> ® 2 MECHANICAL LINE LEAK DETECTOR(MI LD)7'HP.T ROUTINELY PERFORMS 3 0 g p h LEAK TESTS AND RESTRICTS OR SHUTS OFF 490-36 <br /> PRODUCT FLOW WHEN A LEAK IS DEIECIED (23 CCR52636) <br /> MLLDMANUFACIURER(S):VaS ago-37 MODEL#(5): LD2000-� 490-38 <br /> ❑ 3 ELECTRONIC LNE LEAK DETECTOR(EI LD)THAT ROUTINELY PERFORMS 3 0&p h LEAK TESTS 123 CCR§26361 490-39 <br /> ELLDMANUFACIURER(S): 490-40 MODEL#(S): 490.41 <br /> PROGRAMMED IN LINE LEAK TEST: ❑ a MINIMUM MONTHLY 0 2 g p h ❑ b MINIMUM ANNUAL O I g p h 490-42 <br /> ELLD DEIECTION OF A PIPING LEAK IRIGGERS AUTOMATIC PUMP SHUIDOWN ❑ a YES ❑ b NO 490-43 <br /> ELLD FAILURE/DISCONNEC'IION TRIGGERS AUIOMAIIC PUMP SHUTDOWN ❑ a.YES ❑ b.NO '90.44 <br /> ❑ 4 PIPE TNT EGRII'Y'TESTING 490-45 <br /> IEST FREQUENCY: ❑ a,ANNUALLY [J b.EVERY 3 YEARS El c.01HER S eci 49046 <br /> ❑ 5.VISUAL PIPE MONITORING 490.48 <br /> FREQUENCY: ❑ a DAILY ❑ b WEEKLY ❑ c MIN.MONIHLY&EACH IIIviE SYSIEM OPERATED• 49049 <br /> _______ _ _ _ _ __ __-§2'6'3-6-(a,-)('3)'] <br /> _ eUlowed for monilorinuMuried e <br /> of unbmergency.,aeueretor Fuelpiping only�er HC25 <br /> S281 )S3) <br /> ❑ 6 SUCTION PIPING MEETS EXEMPTION CRITERIA.[-23-C"-CR- <br /> 23 CCR§2636!4x31] 490-50 <br /> ❑ 7.NO REGULATED PIPING PER HEALTH AND SAFETY CODE,DIVISION 20,CHAPTER 6.7 IS CONNECTED TO THE TANK SYSTEM. 490-51 <br /> C399.OTHER(Specify) 490-52. <br /> 490-s3. <br /> Arco 06080,Belshire Environmental Services Page T of 6 <br />