Laserfiche WebLink
Spargero Analytical Laboratory Division <br /> Technoboyinc. Mobile Laboratory Division <br /> Scientific Division <br /> With Automation in Mind <br /> I Sample Description <br /> See attached Samples Description Information. <br /> The samples were received under chain-of-custody. <br /> II Analysis Request <br /> The following analytical tests were requested: <br /> Lab ID Your ID Analysis Description <br /> ST93-07-044A Bl-30 Total Lead <br /> ST93-07-045A 132-30 Total Lead <br /> ST93-07-046A 133-30 Total Lead <br /> ST93-07-047A 136-15 418.1 <br /> III Quality Control <br /> A. Project Specific QC. No project specific QC (i.e., spikes and/or <br /> duplicates) was requested. <br /> B. Method Blank Results. A method blank is a laboratory-generated <br /> sample which assesses the degree to which laboratory operations and <br /> procedures cause false-positive analytical results for your sample. <br /> No target parameters were detected in the method blank associated <br /> with your sample at the reporting limit levels noted on the data sheets <br /> in the Analytical Results section. <br /> Accuracy is measured by Percent Recovery as in: <br /> % recovery = (measured concentration) x 100 <br /> (actual concentration) <br /> IV Analysis Results <br /> Results are on the attached data sheets. <br /> 3050 Fite Circle, Suite 112 • Sacramento, California 95827 9 (916) 362-8947 9 FAX(916) 362-0947 <br />