My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
632
>
2200 - Hazardous Waste Program
>
PR0514415
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 1:53:42 PM
Creation date
5/7/2020 10:04:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0514415
PE
2220
FACILITY_ID
FA0002387
FACILITY_NAME
KEYSTONE AUTOMOTIVE INDUSTRIES INC
STREET_NUMBER
632
Direction
S
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
14907033
CURRENT_STATUS
02
SITE_LOCATION
632 S EL DORADO ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
451
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
July 12, 2002 Lab ID STK233284 <br /> Keystone Automotive ndustries, Inc. Customer : 3-12628 <br /> Quality Control - Inorganic <br /> Constituent Method Date/ID Type Units Conc. QC Data DQO Note <br /> Metals <br /> Zinc 3050B 06/27/2002:A209 LCS mg/kg 40.00 99.3% 85-115 <br /> PDS mg/kg 40.00 91.3% 75-125 <br /> MS mg/kg 40.00 98.0% 75-125 <br /> (SP 205892-01) MSD mg/kg 40.00 82.9% 75-125 <br /> MSRPD mg/kg 9.4% 520 <br /> 6010B 06/28/2002:A 10-CCB mg/L ND <0.02 <br /> 10-CCV mg/L 0.5000 97.7% 90-110 <br /> I1-CCB me/L ND <0.02 <br /> 11-CCV mg/L 0.5000 97.2% 90-110 <br /> Definitions <br /> Blank Method Blank - Prepared to verify that the preparation process is not contributing contamination to the samples. <br /> LCS Laboratory Contr I Standard/Sample - Prepared to verify that the preparation process is not affecting analyte <br /> recovery. <br /> PDS Post Digestion S ike (ICP/GFAA) <br /> MS/MSD Matrix Spikes - A random sample is spiked with a known amount of analyte. The recoveries are an indication o <br /> how that samplt matrix affects analyte recovery. <br /> CCB Continuing Calibiation Blank - Analyzed to verify the instrument baseline is within criteria. <br /> CCV Continuing Calib ation Verification - Analyzed to verify the instrument calibration is within criteria. <br /> ND Non-detect - Result was below the DQO listed for the analyte. <br /> DQO Data Quality Ob ective - This is the criteria against which the quality control data is compared. <br /> STK233284: Quality Control Page 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.