Laserfiche WebLink
i <br /> Additional Site Assessment and Aquifer Pump Test Work Plan <br /> MOORE TRUCK LINES <br /> 3400 Newton Road,Stockton, California <br /> 1.0. INTRODUCTION <br /> On behalf of Mrs.Edna Moore of Moore Truck Lines,Advanced GeoEnvironmental,Inc.(AGE)has <br /> prepared the enclosed Additional Site Assessment and Aquifer Pump Test Work Plan for the property <br /> located at 3400 Newton Road,Stockton,California(the site).Th�e proposed scope of work includes <br /> the installation of three monitoring wells screened from 55-75 feet below surface grade (bsg), one <br /> monitoring well screened from 60-80 feet bsg at the former underground storage tank(UST)area, <br /> and performance of one ground water extraction pilot study(pump test)for a duration of 48 hours. <br /> The location of the site is illustrated on Figure 1. A plan of the site, including former soil borings <br /> and proposed well locations, is illustrated on Figure 2. Site background information is provided in <br /> Appendix A. <br /> The purpose of the proposed scope of work is to further assess the extent of total petroleum <br /> hydrocarbons as gas(TPH-g),TPH-diesel,methyl tertiary butyl ether(MTBE),and benzene,toluene, <br /> ethylbenzene, and total xylenes (BTEX)-impacted soil and ground water, and to evaluate ground <br /> water extraction as a remedial alternative for the site. <br /> During the 31 August quarterly ground water monitoring event,the depth to ground water in well <br /> MW-1 was greater than the screen interval. During the 29 November quarterly ground water <br /> monitoring event,the depth of water measured in the well MW-1 screen was approximately one-foot. <br /> On the same day,the depth to ground water measurements were taken in all wells and ranged from <br /> 62.72 in well MW-2 and 62.98 in well MW-1,which had a total depth of 63.10 feet below the casing <br /> grade (MW-1). During both events AGE was unable to collect ground water samples from <br /> monitoring well MW-1.A well with a deeper screen is needed at well MW-1 to address the ground <br /> water contamination at the former UST area and to evaluate ground water remediation feasibility. <br /> This work plan was prepared as required by the San Joaquin County Environmental Health <br /> Department(EHD)by letter dated 05 October 2007(Appendix B). This work plan is in accordance <br /> with the Central Valley Regional Water Quality Control Board's(CV RWQCB's)AppendixA to Tri- <br /> Regional Recommendations-Reporting,dated 30 August 1991, for the investigation of UST sites. <br /> 2.0. SCOPE OF WORK <br /> The proposed scope of work includes the following tasks: <br /> • Permitting and pre-field work activities; <br /> • Soil sample collection and analysis; <br /> • Monitoring well installation and development; <br /> Advanced GeoEnvironmental,Inc. <br />