My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
REPUBLIC
>
14720
>
2900 - Site Mitigation Program
>
PR0542085
>
ARCHIVED REPORTS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 3:18:39 PM
Creation date
5/7/2020 3:08:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
RECORD_ID
PR0542085
PE
2965
FACILITY_ID
FA0010858
FACILITY_NAME
SJC PUBLIC WORKS /UTILITY-FLAG CITY
STREET_NUMBER
14720
STREET_NAME
REPUBLIC
STREET_TYPE
St
City
LODI
Zip
95242
APN
05532009
CURRENT_STATUS
02
SITE_LOCATION
14720 Republic St
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
321
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' 1 C. Contractor shall be responsible for making minor changes in the piping, and equipment <br /> 2 locations due to structural obstructions or conflicts with work specified in other divisions. <br /> 3 <br /> 4 2.02 FABRICATED STEEL <br /> 5 <br /> 6 A. All steel members used in the fabrication of the equipment shall conform to the <br /> 7 requirements or "Specifications for Structural Steel". ASTM A36. All stainless steel shall be <br /> 8 Type 316 unless otherwise specified. <br /> 9 <br /> ' 19 B. Design and fabrication of Structural Steel Members shall be in accordance with the latest <br /> 11 edition of AISC "Specifications for the Design, Fabrication, and Erection of Structural Steel <br /> 12 Plates, Bars and Strip", Designation A-123, or of the ASTM Standard Specifications for Zinc <br /> 13 Coating (Hot Dip) or Iron and Steel Hardware, Designation A153067, as appropriate for <br /> 14 Buildings. All welding shall conform to the latest standards of the American Welding <br /> 15 Society. <br /> 18 <br /> ' 17 C. All parts shall be amply proportioned for all stresses which may occur during fabrication, <br /> 18 erection, and operation. <br /> 19 <br /> 20 2.03 BOLTS, NUTS, AND WASHERS <br /> 21 <br /> zz Bolts for the equipment assembly shall be hexagonal, refined bar iron, except where the <br /> 23 equipment body is stainless steel, aluminum, or bronze alloy, the bolts shall be the same <br /> 24 corrosion resistant material. Nuts shall be hexagonal, of the same metal as the bolts. All <br /> 25 threads shall be clean cut and shall conform to U.S. Standard B1.1 for Unified Screw <br /> 26 Threads. <br /> 27 <br /> ' 28 2.04 NAMEPLATES <br /> 29 <br /> 30 Equipment nameplates shall be engraved or stamped on stainless steel and fastened to the <br /> 31 equipment in an accessible location with oval head stainless steel screws or drive pins. <br /> 32 <br /> 33 2.05 EQUIPMENT MOUNTS, GROUTING, AND VIBRATION ISOLATION <br /> 34 <br /> 35 A. Equipment mountings shall be as shown. Where a steel or cast base is shown between <br /> 36 the equipment and a concrete pedestal, it shall be painted after fabrication in conformance <br /> 37 with applicable provisions of Section 09900. It also shall be equipped with drain pans and <br /> ' 38 drain connections, where applicable. <br /> 39 <br /> 40 B. All concrete plan dimensions for bases or pedestals shall be at least 2 inches larger in <br /> ' 41 each dimension than the steel or cast base installed thereon. Conduits, piping <br /> 42 connections, drains, etc., shall be installed as shown on the Drawings, and/or standard <br /> 43 mechanical details. <br /> 44 <br /> ' 45 C. Where specified or noted in the Drawings, the equipment including the base, shall be <br /> 46 mounted on or suspended from vibration isolators to prevent the transmission of vibration <br /> 47 and mechanically transmitted sound to the supporting structure. Vibration isolation <br /> ' 48 available internally in the equipment unit is not equivalent and shall not be provided when <br /> 49 vibration isolation as specified herein is required. Normally provided internal vibration <br /> 50 isolators need be replaced with rigid supports in such cases. <br /> 51 <br /> GENERAL MECHANICAL EQUIPMENT PROVISIONS <br /> 081294 11010-3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.