My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0013219
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MCKINLEY
>
11168
>
2600 - Land Use Program
>
PA-1700109
>
SU0013219
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/1/2020 1:01:18 PM
Creation date
5/7/2020 3:22:00 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0013219
PE
2632
FACILITY_NAME
PA-1700109
STREET_NUMBER
11168
Direction
S
STREET_NAME
MCKINLEY
STREET_TYPE
AVE
City
FRENCH CAMP
Zip
95231-
APN
19332020, 19332024
ENTERED_DATE
5/1/2020 12:00:00 AM
SITE_LOCATION
11168 S MCKINLEY AVE
RECEIVED_DATE
4/28/2020 12:00:00 AM
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
TSok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1. A building permit for each separate structure or building is required. Submit plans, <br /> Specifications and supporting calculations, prepared by a Registered Design Professional <br /> (architect or engineer) for each structure or building, showing compliance with The 2016 <br /> California Building, Existing Building, Mechanical, Plumbing, Electrical, Energy and Fire Codes <br /> as may be applicable. Plans for the different buildings or structures may be combined into a <br /> single set of construction documents. <br /> 2. The required plans must be complete at the time of submittal for a building permit. Plans must <br /> address building design and construction, fire and life safety requirements, accessibility and <br /> show compliance with the current California codes and San Joaquin County ordinances. A <br /> complete set of plans must include fire sprinkler plans (if required), truss design submittals, <br /> metal building shop drawings, structural plans and calculations, plumbing, electrical and <br /> mechanical drawings and energy report. <br /> 3. A soils report is required pursuant to CBC § 1803 for foundations. All recommendations of the <br /> Soils Report shall be incorporated into the construction drawings. <br /> 4. For each proposed new building, provide the following information on the plans: <br /> A. Description of proposed use <br /> B. Existing and proposed occupancy Groups <br /> C. Type of construction <br /> D. Sprinklers (Yes or No) <br /> E. Number of stories <br /> F. Building height <br /> G. Allowable floor area <br /> H. Proposed floor area <br /> I. Occupant load based on the CBC <br /> J. Occupant load based on the CPC <br /> 5. If high piled combustible storage is to be used in a building, an automatic fire sprinkler system <br /> will be required. <br /> 6. Accessible routes shall be provided per CBC§ 11 B-206.At least one(1)accessible route shall <br /> be provided within the site from accessible parking spaces to the accessible building or facility <br /> entrance they serve. Where more than one(1)route is provided, all routes must be accessible. <br /> §11 B-206.2.1 <br /> 7.Parking spaces will be required to accommodate persons with disabilities in compliance with <br /> Chapter 11 B of the California Building Code. Note that accessible parking spaces are required <br /> for each phase of the project. These parking space(s) shall be located as close as possible to <br /> the primary entrance to the building. <br /> 8. Adequate sanitary facilities shall be provided for the facility, per the requirements of Chapter 4 <br /> of the California Plumbing Code. <br /> 9. Pursuant to Table 4-3 of the California Plumbing Code, toilet facilities shall be accessible to <br /> employees at all times, should not be more than 500 feet from where employees are regularly <br /> employed and accessible by not more than one flight of stairs. The plans shall indicate the <br /> location of the toilet facilities and the travel distance from work areas. <br /> 10. This project will be required to comply with the Model Water Efficient Landscape Ordinance <br /> requirements of the California Code of Regulations, title 22, Division 2, Chapter 2.7 <br /> PA-1700109—Conditions of Approval 3 <br />