My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0009241
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TOSTE
>
2353
>
2900 - Site Mitigation Program
>
PR0231735
>
ARCHIVED REPORTS_XR0009241
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/8/2020 9:33:16 AM
Creation date
5/8/2020 9:20:52 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0009241
RECORD_ID
PR0231735
PE
2381
FACILITY_ID
FA0003778
FACILITY_NAME
TRACY MARINE SALES
STREET_NUMBER
2353
STREET_NAME
TOSTE
STREET_TYPE
RD
City
TRACY
Zip
95376
CURRENT_STATUS
02
SITE_LOCATION
2353 TOSTE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
13 March 2005 <br /> AGE-NC Project No 96-0263 <br /> IPage 3 of 4 <br /> 3 2 ANALYTICAL RESULTS OF GROUND WATER SAMPLES <br /> TPH-g was detected in water samples MW-2, MW-4, MW-5 and MW-7 at concentrations ranging <br /> from 100 micrograms per liter (µg/1) in MW-4 to 12,000 µg/1 in MW-7 <br /> Benzene was detected in water samples MW-2, MW-5 and MW-7 at concentrations ranging from <br /> 4 1 µg11 in MW-2 to 140 µg/1 in MW-7 Toluene, ethylbenzene and total xylenes were detected in <br /> one or more of the same wells at concentrations as high as 52 µg/1, 56 µg11 and 129 µg/1,respectively <br /> (MW-7) <br /> MTBE was detected in samples MW-2, MW-4, MW-5, and MW-7 at concentrations ranging from <br /> 48 µg/l(MW-5)to 11,000µg/l(MW-7) TAME and 1,2-DCA were detected in the sample collected <br /> from well MW-7 at concentrations of 7 5 µg/l and 3 7 µg/l, respectively No other fuel additives <br /> were detected in the ground water samples collected from the site <br /> The current and past ground water sample analytical results are summarized in Tables 2 and 3 <br /> Copies of the laboratory report (CTEL Project No CT214-0411062), quality assurance/quality <br /> control (QA/QC) report and chain of custody forms are in Appendix C GeoTracker confirmation <br /> pages of the submitted laboratory electronic deliverable format (EDF) files are included in <br /> Appendix D <br /> 33 OZONE INJECTION PILOT TEST <br /> Ozone injection began at the site on 01 June 2004 The ozone injection operational protocol, as <br /> established by ozone units designer manufactures, follows the recommended two-hour ozone <br />' injection cycle at each sparge-point The injection rate is approximately 10 pounds per squar inch <br /> (psi)to displace the ground water within the sparge wells and no greater than 2 cubic feet per minute <br /> (CFM) to inject the ozone <br /> After completing a cycle through all nine ozone wells, the ozone injection ceases for a 2-hour <br /> mechanical hiatus, after which, the injection cycle through all of the sparge wells restarts <br /> 1 <br /> 4.0. SUMMARY AND CONCLUSIONS <br /> Based on the results of this investigation, AGE concludes that <br /> Depth to ground water ranged from 6 80 feet to 8 12 feet below the tops of the well casings <br /> • Ground water elevations at the site ranged from 28 75 feet above MSL in well MW-9 to <br />' Advanced CcoEnvironmental,Inc <br />