My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008 - 2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
85
>
2300 - Underground Storage Tank Program
>
PR0231656
>
COMPLIANCE INFO_2008 - 2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/26/2022 1:11:57 PM
Creation date
5/8/2020 3:44:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008 - 2011
RECORD_ID
PR0231656
PE
2351
FACILITY_ID
FA0003635
FACILITY_NAME
ARCO 06080
STREET_NUMBER
85
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
LATHROP
Zip
95330
APN
19627010
CURRENT_STATUS
01
SITE_LOCATION
85 E LOUISE AVE
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
337
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
State Water Resources Control Board Page 1 of 2 <br /> Home >>Water Issues >>Programs >>Ust > Leak Prevention >Lg113 >>Vendors <br /> UST Programs- LG 113 <br /> ......................................................................................................................................................................................... <br /> Issue Date:August 23,1999 <br /> Revision Date:March 11,2004 <br /> Vaporless Manufacturing <br /> Vaporless 98LD-2000,991-D-2000,99LD-2200, LD-2200 Scout <br /> (for Rigid and Flexible Pipelines) <br /> AUTOMATIC MECHANICAL LINE LEAK DETECTOR <br /> Certification Leak rate of 3.0 gph with PD = 100% and PFA = 0%. <br /> Leak 2.5 gph. <br /> Threshold A pipeline system should not be declared tight if the test result indicates a loss that equals or exceeds this <br /> threshold. <br /> Applicability Gasoline, diesel, aviation fuel. <br /> Other liquids may be tested after consultation with the manufacturer. <br /> Specification System tests pressurized flexible, fiberglass, and steel pipelines. <br /> Tests are conducted at operating pressure. <br /> Pipeline Maximum of 172 gallons for rigid pipelines. <br /> Capacity Maximum of 39.5 gallons for flexible pipelines. <br /> Waiting Time None between dispensing and testing. <br /> None between delivery and testing. <br /> Test Period Response time is less than 1 minute without a leak and 1 to 8 minutes with a leak. <br /> System Permanent installation on pipeline. <br /> Features Automatic testing of pipeline. <br /> Preset threshold. <br /> Single test to determine if pipeline is leaking. <br /> Restricted flow to dispenser if leak is declared. <br /> Calibration Equipment must be checked annually for capability of detecting a line leak of 3.0 gph and,if <br /> necessary,calibrated in accordance with manufacturer's instructions. <br /> Comments Functionality and operability of the 99 LD-2000 and 99 LD-2200 are unchanged by installation of the Leak <br /> Detection Sensor(piston switch)that supports the VMI ISM-4080 and ISM-4081 Integrated Shutdown Module. <br /> Vaporless Manufacturing Evaluator: Ken Wilcox Associates <br /> 8700 East Long Mesa Drive Tel: (816) 443-2494 <br /> Prescott Valley,AZ 86314 Dates of Evaluation: 05/20/98, 11/10/98 <br /> Tel: (928) 775-5191 <br /> 1 Home I Vendors:A-F I Vendors:G-M_ I Vendors:N-S I Vendors:T-Z I Method Index <br /> Appearance on this list is not to be construed as an endorsement by any regulatory agency nor is it any guarantee of the <br /> performance of the method or equipment. <br /> Equipment should be installed and operated in accordance with all applicable laws and regulations. <br /> http://www.waterboards.ca.gov/water_issues/programs/ust/leak_prevention/lg 113/vendors/... 3/18/2010 <br />
The URL can be used to link to this page
Your browser does not support the video tag.