Laserfiche WebLink
EQUIPMENT LIST <br /> JAj DESCRIPTION MANUFACTURER MODEL j PART j <br /> Oj 42' DIAMETER MULTI-PORT SPILL CONTAINMENT MANHOLE & FRAME POMECO 521 65718-EVR- IM42RT052 IFF 2 PHASE I BRONZE SWIVEL ADAPTER W/ OPW JVPN 4x5 NIPPLE OPW 61VSA-EVR 61VSA-1020-EVR <br /> 5 QN'M�r � 3 PHASE I VAPOR TOP SEAL CAP OPW 1711T-EVR 1711T-7085 <br /> INTERSTATE r O CCAASTE6iON W/DRAINV�ESPL GC OPW NJ� IDK 21W ON POMECO 511 511C-PEVR <br /> EXISTING VENT RISERS 5 FACE SEAL ADAPTER, PHASE I RISER, ATG RISER, & FILL RISER OPW FSA-400 FSA-400 <br /> a O > O <br /> 7 13 O6 FlLL BRNZE SWIVEL ADAPTER W/ DPW JFPN 4x7 NIPPLE OPW 61SALP-EVR BISALP- 1020-EVR —J 0 � (n Q <br /> INSTALL NEW OVERFILL ALARM <br /> W/ ACKNOWLEDGMENT - - Oj FILL TOP SEAL CAP OPW 63417-EVR 63417-7085 oadd, , 1_ O <br /> SWITCH IpFILL SPILL CONTAINMENT. 5 GALLON CAST IRON, POMECO 511 511C-DEUR <br /> / Q /EVR GRAIN VALVE U o <br /> PI, a 9 JACK SCREW ASSEMBLY IN FILL BUCKET OPW 61JSK-4400-EVR 61JSK-4400-EVR •O <br /> doo <br /> Joao e e (' PLANTER <br /> 10 STRAIGHT FILL DROP TUBE OPW 61T 611'-7368 E ' C d� <br /> A� , II 12 TANK GAGE PORT COMPONENTS (GP & RING KR)11 FITTING, EXTRACTOR, TEE, 4'X4' L <br /> X3'X3' OPN 233 233VM-4433 <br /> Q e I MORRISON BROS, 305XPAIIOOAKEVR 305XPA1100MEVRR 5✓ m <br /> II 623V-22032w) <br /> THREADED PRESSURE VENT CAP OPW 623V 623V-3203 43, <br /> U <br /> •+� - <br /> Cf) cD <br /> / II 14 NOT USED c <br /> EXISTING <br /> FILL SUMP (TYP.) O O <br /> II ® 2 3 4 <br /> @_ 3' X 12' BALLFLOAT OPW 53VML-3120 53VML-3120 0 — <br /> ® 0P1Y PMWS MAWS-33 (33' TOP FIAT) <br /> �I 5 6 8 11 16 WATER SHIELD _ <br /> o w 0 651 1 -8816 65113 8166 (36' TOP HAT U <br /> EXISTING U,C. o: 17 RISER SUPPORT OPW �- M <br /> STORAGE TANKS "' S 0 <br /> 0 e I VR-790091 -001 ALARM (V <br /> h ?7 18 OVERFILL ALARM WITH HORN/STROBE 120VAC, VEEDER-ROOT Vft-790095-001 SWITCH CD <br /> ANNULAR MONITOR S o I ACKNOWLEDGE SWITCH, & AUTOMATIC TANK GAUGE <br /> o' <br /> I VR-847390-10X TANK GAUGE O <br /> EXISTING TURBINE O w m O Ida a <br /> SUMP (TYP.) O O VEEOER-ROOT <br /> I TLS—� <br /> EX�NG TANK �MNTTOR SYSTEM m Q <br /> ffffff EXISTING BUILDING <br /> ® I a <br /> ALARM 2'-0' 1 2'-0' 200x14'x1/4' z E <br /> ACKNOWLEDGE STEEL PLATE C3 <br /> NL I SWITCH OVERFILL PAINT TO <br /> w a ALARM MATCH SITE 0 IL <br /> m I 6' 0 BOLLARD TCONDITIONS L L0 <br /> FILL W/ CONC. 1 a <br /> Q OYP. 2) 0 Q W J <br /> EXISTING <br /> E50 O 1— <br /> N E.S.O. I I I I WP ENCL.Foom J Q <br /> r joaddo <br /> M EXISTING CANOPY I I I p_ RECMT. adds Q V) <br /> 0 I EXISTING CARD I 4'x4' STEEL 12' / 7-1 � <br /> READER I I MATCHPOST PAINT SITE TO TIGHT FLEX c —7� � <br /> e Oe i I CONDITIONS 4•0• a <br /> SEAL-OFF JUNCTION <br /> 1 ' RGS CONDUIT BOX <br /> EXISTING ry-1CL <br /> DISPENSERS <br /> SERS N I I I FINISHED <br /> m W Q <br /> 0 o EXISTING I I - ad I > Z LL <br /> CANOPY I I : 't N a N <br /> ✓� COLUMN (EYP.) ION <br /> ' NHOLE 3 PHLAS <br /> ASE I CAP �j i O W <br /> I I I r � � V) <br /> BUCKET (NO <br /> O <br /> FILL <br /> CAP 2 PHASE I lm RGS ROTATABLE COATED PVC } , • "ad F , I O < Z <br /> \ q <br /> DRIVE <br /> I I TATABLE CONDUIT 18'1 CNCR • FOOTING �/ J U a- <br /> qY I R 16 BY G.C. (TYP.) > 0 � <br /> 4 °s I FILLALLON 4 PHASE 15 2 OVERFILL ALARM N.T.S. N o <br /> �d,Kw 88 <br /> , \ (W/ GALLON Q <br /> \ ALVE) BUCKE to <br /> DRAIN VALVE) W F" I-- <br /> � REW 12 ATG CAP AND :y . LLI DOJ <br /> FLAMER LYRING KIT 1• ; :5 FACE SEALAdo <br /> DAPTERAL 11 EXTRACTOR(BEYOND)ITENAGAPTE0 <br /> 4'x12' L BLACK us <br /> RISER UPPORT STEEL RISER W/ <br /> 17 PIPE CM N o � ' 0 <br /> hD <br /> 15 BALL FLOAT EXTRACTOR HID <br /> � 4 <br /> VALVE LOCATED FITTING tE n �. <br /> 20' 0 20' 40' 60' DROPGTUBE ACjPACITY 11 EHH... � roFIBI� <br /> VWdodo NMu. <br /> W wD <br /> INSTALLATION NOTES : ID SET ALARM BALL FLOAT VALVE J 3:z <br /> Zw000r <br /> BEFORE STMT OF SAW CUTTING, REMEASURE TO CONFIRM THAT EXISTING MANHOLE FRAME IS NOT COMPATIBLE 90x LOCATED AT 95% NEDO <br /> WITH NEW MANHOLE UD, IF UD IS COMPATIBLE, DO NOT CUT UNTIL FIELD ENGINEER WAS CONFIRMED A NEED C GRAPHIC SCALE 1B nO = a I <br /> 105 NJO. wW <br /> REFUGE MANHOLE FRAME. z 4ERECt1oN <br /> LT NOTE <br /> CONTRACTOR TO SAW CUT 6' X 6' MINIMUM SECTIONS OF EXISTING TANK SLAB AT EACH MANWAY AN SHOWN. PULE <br /> cc <br /> ® CONTRACTOR TO REMOVE EXISTING FILL SPILL BUCKETS. REMOVE EXISTING DROP TUBE FLAPPER VALVE (IF MY), <br /> AND ANY NON—EVR BALL FLOATS. AS <br /> ( CONTRACTOR TO INSTALL NEW EVR SWIVEL RISER ADAPTERS AND THREADED NIPPLES AT EACH VAPOR & FILL RISER. HIS SATE PLAN HAS BEEN PREPARED WITHOUT <br /> BENEFIT OF TITLE REPORT, SURVEY, OR LEGAL consultant J <br /> 04NT <br /> CORACTOR TO INSTALL NEW 5 GALLON SPILL CONTAINMENT BUCKETS AND MANHOLE W/ FRAME AT EACH TANK DESCRIPTION. DRAWING REFLECTS EXISTING SITE STAGE I VAPOR RECOVERY & 0888 84 <br /> 4 <br /> FILL EVR VR- 102-8 COMPLT, INSTALL NEW WATER SHIELD AND RISER SUPPORTS AT EACH FILL SUMP. 3 TYPICAL TURBINE ELEVATION H.T.S. master release data <br /> CONDITIONS AS MEASURED. <br /> OCONIRACTOR TO INSTALL NEW FILL DROP TUBE AND BALL FLOATS AT EACH TANK. EVR VR-102-8 COMPLIANT. FILL DETAIL ( GASOLINE ) <br /> © CONTRACTOR TO INSTALL NEW RISER COMPONENTS AT EXISTING TANK GAUGE RISERS. FIELD VERIFY EXACT RISER - Protect rt1.alar <br /> N0. BP WEST COAST PRODUCTS, LLC MASTER REVISIONS axe dale dradoo <br /> wn by <br /> LOCATION* EVR VR-102-B COMPLM. Underground Service Alert PROPRIETARY AND COFIDENT u.� NPORMATION NO. 1 DATE I REVISIONS BY PROJECT RELEASE 12/09/0.1 JWD <br /> (D CONTRACTOR TO INSTALL NEW PRESSURE VACUUM VENT VALVE AT EACH GASOLINE VENT RISER. THIS DOCIIUENT ,AND THE INFORVATION MEN REGABNO To ram FIEDLER 1/07/0 REV. EQUIP. CHANGE PER BP AL2 09 p3 Filename — — <br /> (CONTRACTOR TO FIELD VERIFY QUANTITY) EVR VR-102—B COMPLIANT, SEE ITEM 113 ON EQUIPMENT UST. C011: TOLL FREE AND ASSOMTU AND Irs CLIENT FM BEEN FLAMMED IN CDNRDOd FOR PERMIT 1 / / <br /> 03 <br /> THE PRNATE USE OF AUD10RZm PEEtsONNE. NO PART HEREOF SEMI BEFaculty Protect <br /> 08 CONTRACTOR TO PATCH ALL REMOVED CONCRETE TO MATCH EXISTING. q p ON4M, "LJCATED, DKTRBUfED, DecIBSED OR MADE AVAILABLE To <br /> 9� NOT USED. 1 - 800'1 FUELING 8 mtExs oa usm T. Am ocmTr xxaTsaE`sn Ecc ASEIPaEmY BID 06080 <br /> 2 61JO AMIDWED IN WAITING BY FRED FOLER ARO ASSOCMTES IIS CUEIT. <br /> ANY PERSON, FEW OR ODRPORAINNI RECFAYIG THIS OOCIMEW, HOWEVER <br /> 10 INSTALL NEW VEEDER—ROOT OVERFILL ALARM W/ ACKNOWLEDGMENT SWITCH AND NEW AUTOMATIC TANK �FORt:6amiNG ESTw Ia� HEREOF BE DEAD TO HxW AWEED TO THE CONST. sheet name <br /> GAGING IF NOT EXISTING. NOZZLES 8 TK 1 - 1 <br /> 11 CONTRACTOR TO INSTALL NEW RISER OFFSET AT VAPOR RISER TO OBTAIN 16' O.C. FOR FILL AND <br /> VAPOR RISERS. (WHEN EXISTING IS LESS THAN 16' D.C. ONLY) TWO WORKING DAYS BEFORE YOU DIG <br /> AS—BUILT <br />