My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2004 - 2007
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
85
>
2300 - Underground Storage Tank Program
>
PR0231656
>
COMPLIANCE INFO_2004 - 2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/26/2022 11:54:19 AM
Creation date
5/8/2020 4:22:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004 - 2007
RECORD_ID
PR0231656
PE
2351
FACILITY_ID
FA0003635
FACILITY_NAME
ARCO 06080
STREET_NUMBER
85
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
LATHROP
Zip
95330
APN
19627010
CURRENT_STATUS
01
SITE_LOCATION
85 E LOUISE AVE
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
384
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Monitoring System Certification <br /> Site Address: 85 E LOUISE AVE Date of Testing/Service: 09/27/2007 <br /> PTO N-71 <br /> D. Results of Testing/Servicing <br /> Software Version Installed: 325.02 <br /> Complete the following checklist: <br /> Q Yes No• Is the audible alarm operational? <br /> Q Yes No• Is the visual alarm operational? <br /> Q Yes No• Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> Q <br /> Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not Yes ❑No interfere with their proper operation? <br /> Yes No x N/A If alarms are relayed to a remote monitoring station,is all communications equipment(e.g.modem)operational? <br /> For pressurized piping systems,does the turbine automatically shut down if the piping secondary containment <br /> M Yes E]No• N/A monitoring system detects a leak,fails to operate,or is electrically disconnected?If yes:which sensors initiate positive <br /> shut-down?(check all that apply) ❑x Sump/Trench Sensors; ❑x Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks aad sensor failure/disconnection? ❑x Yes No <br /> Mx Yes O No• N/A For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e.:no mechanical <br /> El overfill prevention valve is installed),is the overfill warning alarm visible and audible at the tank fill points(s)and operating <br /> properly? If so,at what percent of tank capacity does the alarm trigger? 90 % <br /> 0 Yes' No Was any monitoring equipment replaced?If yes,identify specific sensors,probes,or other equipment replaced and list the <br /> manufacturer name and model for all replacement parts in Section E,below. <br /> Yes' No Was liquid found inside any secondary containment systems designed as dry systems?(check all that apply) ❑Product; <br /> ❑ Water. If yes,describe causes in Section E,below. <br /> EX Yes El No Was monitoring system set-up reviewed to ensure proper settings?Attach set-up reports,if applicable. <br /> Q Yes No• Is all monitoring equipment operational per manufacturers'specifications? <br /> In Section E below,describe how and when these deficiences were or will be corrected. <br /> E. Comments: <br /> 89/GRADE MECHANICAL LEAK DETECTOR FAILED INITIAL TEST. (VAPORLESS/LD-2000)REPLACED OLD LEAK DETECTOR <br /> WITH NEW MECHAICAL LEAK DETECTOR. (VAPORLESS/LD-2000) RETESTED NEW LEAK DETECTOR AND NEW LEAK <br /> DETECTOR CONFIRMED OPERATIONAL. ALSO SITE IS EQUIPED WITH VAPOR SUMP,AND PRODUCT SUMP BOTH WITH <br /> VEEDER ROOT SENSORS MODEL#323. BOTH SENSORS TESTED AND CONFIRMED OPERATIONAL. <br /> Page 2 of 3 Based on CA form dated 03/01 <br />