Laserfiche WebLink
HUNTER ENVIRONMENTAL SERVICES, INC., FINAL TEST RESULTS - <br /> 18350 MT. LANGLEY STREET, SUITE 101 TEST DATE: 3/18/88 <br /> FOUNTAIN VALLEY, CA 92108 <br /> 800-247-9014 800-247-2186 <br /> CUSTOMER: ARCO LOCATION/IDENTIFICATION NO.: 6080 <br /> ADDRESS: 85 LOUISE <br /> LATHROP, CA <br /> TEST RESULTS SUMMARY <br /> LEAK LOKATOR RESULTS <br /> --------------------------------------------------------- <br /> SYSTEM ----TANK-SIZE---- <br /> WATER LEVEL ALR <br /> ---- ---- <br /> NO. PRODUCT GALLONS DIA/MATL INCHES INCHES GPH CONCLUSION RECOMMENDATIONS <br /> --- --------- <br /> S/U 12000 92/FG 0 153 ULLAGE LEAK <br /> 113 -,020 TIGHT <br /> 2 U/L 12000 92/FG 0 167 -1.025 LEAK <br /> 112 INCONCLUSIVE <br /> 3 REG 12000 -2/FG 0 151 -.027 TIGHT <br /> ii <br /> OTHER INFO: COULD NOT RID UNLEAD SYSTEM OF EXCESSIVE AIR. f" <br /> PRODUCT LINES - HYDROSTATIC PRESSURE TEST RESULTS <br /> SYSTEM ---TYPE-OF-PUMP--- <br /> POUNDS POUNDS MINUTES PRODUCT PRODUCT CONCLUSION <br /> ---- -- ---- <br /> N0. PRODUCT REMOTE SUCTION APPLIED HELD HELD LOSS CC's LOSS GPH iP.ESL!LT <br /> --------------------------------------------------------------------------------------------------/RESUL-------- <br /> 1 S/U RED JACKET 5:) 10 PASS <br /> 2 U/L RED JACKET 50 10 PASS <br /> 3 REG RED JACKET 50 10 PASS <br /> NOTE: On suction systems, NEVER put more than 15 psi on any pump system. <br /> DETAIL OF TEST RESULTS <br /> TEST TIMELEAK RATE TEMPER'ATUR'E ABSOLUTE CHECK <br /> SYSTEM TEST LEVEL CLOCK DURATION COMPENSATION LEAK RATE TEST <br /> NO. PIPODUCT NO, (IN,) STATE (.HR-MIN) CC DIV �C:/MTN DELTA of CCJMTN CCIMT_N GPH VIN <br /> ------------------------------------------------------------------------------------------------------------------- <br /> 1 S/U 1 113 3:30 :32 11.780 +4,624 +,012 +5,905 -1,281 -.020 N <br /> 2:27 :33 .661 -12.025 -.015 -1.381 -64.664 -1.t�25 N <br /> 2 U/L 1 167 <br /> 3 REG 1 151 12:52 :33 6.2'"36 +13,867 +.028 +15.597 -1.330 -.027 N <br /> *LEVEL - Inches from Tank Bottom to Test Level <br /> ALR - Absolute Leak Rate (Measured Leak Rate - Temperature Compensation) in Gallons Per Hour <br /> CONCLUSION - NFPA 329 criterion of +/- 0.05 GPA is used to certify tightness <br /> CERTIFICATION CERTIFIED <br /> This is to certify that the above tank systems were tested, using the HUNTER ENVIRONMENTAL SERVICES, INC. LEAK <br /> LOKATOR according to all standard operating procedures. Those indicated as tight at full system Beet the criterion <br /> established by the National Fire Protection Association Pamphlet 329 for Precision Testing, <br /> Tests Conducted and Certified By: Test Van No. 30 <br /> Team Manager: E. GULLY <br /> Tank Testing Specialist: D. BOBER <br />