Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department DIRECTOR <br /> ?' —�f•'•� Donna Heran,REHS <br /> 600 East Main Street <br /> m { Stockton, California 95202-3029 PROGRAM COORDINATORS <br /> Robert McClellon, REHS <br /> �. Jeff Carruesco,REHS, RDI <br /> co ` ��° Website: www.sjgov.org/ehd Kasey Foley, REHS <br /> QFOR Phone: (209) 468-3420 Linda Turkatte, REHS <br /> November 5, 2010 Fax: (209)464-0138 <br /> Liddy McKenzie <br /> Gettler Ryan Inc <br /> 6747 Sierra Court <br /> Dublin, CA 94568 <br /> Re: Arco #6080 SR0061244 <br /> 85 East Louise Ave, Lathrop 95330 <br /> The San Joaquin County Environmental Health Department(EHD) has completed the initial <br /> review of the permit application to install the following underground storage tank (UST) system <br /> at the above noted address: <br /> 20,000 gallon UST (ID#39-000231656-0519980) regular unleaded, <br /> 12,000 gallon UST (ID#39-000231656-0519981) premium unleaded (split tank w/diesel), <br /> 10,000 gallon UST (ID#39-000231656-0519982)diesel (split tank with premium unleaded), <br /> along with the associated piping, four dispensers, turbine pumps, and appurtenances. <br /> The permit cannot be approved until the following items are submitted: <br /> 1. Copies of manufacturer cut sheets for all components used, including but not limited to: <br /> tanks, piping, monitoring equipment, spill containment devices, overfill protection <br /> devices, dispenser pans, penetration fittings, along with documentations showing third- <br /> party testing that meets California Code of Regulations, Title 23, Section 2631(b) <br /> requirements. <br /> 2. Installation instructions for the Containment Solutions tanks. <br /> 3. A completed work plan, separate application permit and fees for ELD installation and <br /> testing. An application is enclosed with this letter. <br /> 4. Three revised pages of Work Plan sheet# M.5.3.08 that reflects the correct size of the <br /> UST and deadman in section "Notes: UST Anchoring", item #4. <br /> 5. Three revised copies of the relevant pages of the Work Plan that reflects the correct <br /> overfill prevention method for the USTs. Sheet# F1, section "Scope of Work" item F <br /> indicates drop tubes to shut off at 95% tank capacity, sheet# M.5.3.01, item #41 <br /> indicates a straight drop tube OPW Model #61T. Drawings on sheets # M.5.3.03 and <br /> M.5.3.04 shows straight drop tubes and sheet#M.5.3.04, section "Notes: UST <br /> Installation", item #15 indicates the use of an overfill alarm set at 90%. <br />