My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
85
>
2300 - Underground Storage Tank Program
>
PR0231656
>
INSTALL_2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/26/2022 4:43:08 PM
Creation date
5/11/2020 2:26:27 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2011
RECORD_ID
PR0231656
PE
2351
FACILITY_ID
FA0003635
FACILITY_NAME
ARCO 06080
STREET_NUMBER
85
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
LATHROP
Zip
95330
APN
19627010
CURRENT_STATUS
01
SITE_LOCATION
85 E LOUISE AVE
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
422
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
C. REQUIRED SUBMITTALS <br /> The following information shall be submitted to San Joaquin County Environmental Health <br /> Department prior to an installation plan review: <br /> 1. TO BE SUBMITTED WITH APPLICATION: <br /> F.-I San Joaquin County EHD Service Request Form and Fee Sheet <br /> 0 Completed Underground Storage Tank System Installation Permit application <br /> Completed: UPCF Underground Storage Tanks - Facility form (A); UPCF <br /> Underground Storage Tanks (B)-Tank (one form per tank) <br /> M•S,3.Ol 4 ,02 <br /> El Manufacturers' cut sheets for tanks, piping, and equipment (e.g. monitoring <br /> equipment, overspill containment device, overfill protection device, dispenser <br /> pan, etc.) <br /> ❑ Buoyancy calculations signed by a Professional Engineer —c*wqQA <br /> ❑ 3-sets of plans of the facility and underground storage tank system along with <br /> specifications on all materials to be used in construction <br /> 0 Payment of appropriate permit fees <br /> DRAWINGS SHALL INCLUDE THE FOLLOWING: <br /> 0 Plans must be drawn to scale in non-erasable ink <br /> 0 Tank cross-sectional drawing <br /> F] Detail of tank, associated piping, excavation and cover <br /> ❑ Plot plan to show location of tanks and all associated piping <br /> ❑ Striker plates or drop tube-mounted bottom protectors illustrated below all <br /> accessible openings <br /> ❑ Under-dispenser containment connections <br /> ❑ Detail of secondary containment installed for all unused tank opening that are <br /> connected to the primary space of the UST <br /> ❑ Detail of sumps and under-dispenser containment to demonstrate vapor tightness <br /> ❑ Detail of system that demonstrates it is impervious to water intrusion. <br /> ❑ Overfill prevention system <br /> ❑ Location of all monitoring equipment <br /> ❑ Location of water wells, septic systems, and storm drains. <br /> Note: Enhanced Leak Detection (ELD) must be performed prior to the final inspection. <br /> A separate permit application is required to install ELD. <br /> Revised 07/22/10 4 <br />