SECTION r — All Single Wall and Double Wall Tanks <br /> • Tank diameter plus 12" to 24" for concrete <br /> Anchoring Chart anchor pad. <br /> Minimum burial depth to achieve 1.2 safety factor <br /> against flotation assuming worst case conditions of * Anchor points must be aligned with designated <br /> water to grade and the tank empty.Assumes multiple ribs (►.) ±1". <br /> tank installation and two deadman widths minimum <br /> spacing. ♦ Place anchor straps in the strap guides over the <br /> designated ribs ( ►.). <br /> Anchoring Minimum Burial Depth FIGURE 10 <br /> Method No 42"w/one Sealed FRP Strap <br /> Wire Rope <br /> (no top slab) Turbine or Watertight Triple <br /> Clamp (Strap Eyelet <br /> Enclosure Turbine Enclosure See Detail) <br /> Double Wall optional <br /> Tank Tumbudde <br /> 4' Diameter Tanks H Assembly <br /> • 8"Bottom Slab 24" 24" __; —� <br /> • 6'x 6"Deadmen 24" 26" <br /> Deadman Anchor Pad <br /> (24"min.spacing) Anchor Tenk End System <br /> • No Mechanical Anchoring 28" 40" system View <br /> 6' Dlameter Tanks FIGURE 11 <br /> Strap Eyelet [Fiberglass Strap <br /> • 8" ottom Slab 24" 24" Galvanized \ <br /> • 12 x 12"Deadmen 27" 30" steel <br /> 24"min.spacing) <br /> • No Mechanical Anchoring 42" 50" <br /> 8' Diameter Tanks s <br /> • 8"Bottom Slab 32" 36" <br /> • 12"x 12"Deadmen 40" 44" A <br /> (24"min.spacing) Flat or Round Strap Eyelet Detail <br /> • No Mechanical Anchoring 55" 60" <br /> 10' Diameter Tanks (10M to 15M Gallon) ANCHOR STRAPS - FLAT <br /> • 8"Bottom Slab 40" 42" Tank FIG. ANCHOR STRAPS <br /> • 18"x 12"Deadmen 40" 42" Dia. 10 FIGURE 11 <br /> (3 "min.spacing) H A B <br /> • No Mechanical Anchoring 62" 66" 4' 13" 1 7/8-1 2 7/8" <br /> 10' Diameter Tanks (Over 15M Gallon to 30M Gallon 6' 27" 1 7/8" 2 7/8" <br /> • 8"Bottom Slab 42" 46" 8' 36" 1 7/8" 2 7/8" <br /> • 181 x 12"Deadmen 48' 50" 10' 42" 1 7/8" 2 7/8" <br /> (36"min.spacing) 12' 58" 1 7/811 2 7/8" <br /> • No Mechanical Anchoring 70' 74" <br /> 10' Diameter Tanks (Over 30M Gallon? ♦ All anchor straps must be uniformly tightened with turn- <br /> * 8"Bottom Slab 51" 55" buckles or come-a-longs. Straps should be snug, but <br /> • 18"x 11"Deadmen 51" 55" not cause tank deflection (see figure 10). <br /> (36"min.spacing) <br /> • No Mechanical Anchoring 72" 75" • Measure tank deflection by measuring tank diameter <br /> before and after snugging straps. <br /> Contact Tank Technical Support for alternate • Use standard nonmetallic gauge stick. <br /> anchoring methods. ♦ See Installation Checklist for specific measurement in- <br /> structions. <br /> MECHANICAL ANCHORING ♦ Triple clamp wire rope. <br /> ♦ Use only Containment Solutions fiberglass anchor straps. * If deflection occurs, loosen straps to allow tank to go <br /> ♦ Use anchor straps specifically designated for each di- back into round. <br /> ameter of tank. Length of strap is different for each <br /> tank diameter. CAUTION <br /> ♦ Maintain proper distance between anchor points on <br /> each side of the tank : Do not use straps between ribs (exception 4' <br /> • Tank diameter plus one deadman width for diameter tanks) or tank damage may occurl <br /> concrete deadmen. <br /> 10 <br />