My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
85
>
2300 - Underground Storage Tank Program
>
PR0231656
>
INSTALL_2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/26/2022 4:43:08 PM
Creation date
5/11/2020 2:26:27 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2011
RECORD_ID
PR0231656
PE
2351
FACILITY_ID
FA0003635
FACILITY_NAME
ARCO 06080
STREET_NUMBER
85
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
LATHROP
Zip
95330
APN
19627010
CURRENT_STATUS
01
SITE_LOCATION
85 E LOUISE AVE
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
422
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Setup and Test <br /> Setting Overfill Alarm Horn Delay Time <br /> 1. Loosen the four screws that secure the Overfill Alarm cover clamps to the case. Slide the clamps away from the <br /> retaining lip on the door.Open the door. <br /> 2. Locate the Horn Time Delay Relay(see Figure 3). <br /> 3. Adjust the time the horn remains On from 0 to 60 seconds by turning the knob on the relay to the desired setting. <br /> 4. Close the door and tighten the four cover screws. <br /> Testing the Overfill Alarm with the Acknowledgement Switch <br /> Turn On power to the Overfill Alarm and Acknowledgement Switch.Depress and hold in the TEST Button on the right <br /> side of the switch.The Overfill Alarm hom will sound immediately,and the Overfill Alarm's red light will start flashing. <br /> The hom will turn Off at the preset delay time you set above(0-60 seconds).The red light will continue to flash until the <br /> TEST button is released. <br /> Setting the Overfill Alarm Horn's Volume Level <br /> 1. Locate the adjustment set screw(1/16"Hex wrench)on the exterior of the Overfill Alarm's hom cover(see Figure 1 <br /> on page 3). <br /> 2. Turn the adjustment screw counterclockwise to increase the dB level of the hom or clockwise to decrease its dB <br /> level. <br /> Testing the Overfill Alarm with the Console <br /> 1. With the Overfill Alarm and Acknowledgement Switch(if installed)connected to the console,consult the setup <br /> instructions for your console and perform the Output Relay setup procedure to recognize the Overfill Alarm. <br /> O 2. Turn power Off to the console and the Overfill Alarm.Put a jumper between the two Overfill Alarm relay <br /> connections in the console. <br /> OOVERFILL ALARM W/O ACKNOWLEDGEMENT SWITCH <br /> 1. Reapply power.If the Overfill Alarm is wired properly,the alarm hom should sound immediately followed by the red <br /> alarm light flashing. <br /> O2. Tum Off power to the console and to the Overfill Alarm.Remove the jumper between the Output Relay connections. <br /> OVERFILL ALARM WITH ACKNOWLEDGEMENT SWITCH <br /> 1. Stand by the Acknowledgement Switch and have someone reapply power to the console and Overfill Alarm.If the <br /> Overfill Alarm is wired properly,the alarm hom should sound immediately followed by the red alarm light flashing. <br /> 7 <br />