My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
85
>
2300 - Underground Storage Tank Program
>
PR0231656
>
INSTALL_2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/26/2022 4:43:08 PM
Creation date
5/11/2020 2:26:27 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2011
RECORD_ID
PR0231656
PE
2351
FACILITY_ID
FA0003635
FACILITY_NAME
ARCO 06080
STREET_NUMBER
85
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
LATHROP
Zip
95330
APN
19627010
CURRENT_STATUS
01
SITE_LOCATION
85 E LOUISE AVE
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
422
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
miRO TECHNICAL BULLFEETINT13009 <br /> 4($� Franklin Fueling Systems May 20, 2004 <br /> Mag-VFC Electrical Installation <br /> The Mag-VFC (Variable Frequency Controller for the IST) electrical installation must be performed <br /> in accordance with the Mag-VFC Installation and Owner's Manual and all applicable Federal, <br /> State, and Local regulations. <br /> The Mag-VFC requires 200-250 Volt, 1 or 3 Phase, 50 or 60 Hz input power and a properly <br /> connected ground. The output power to the IST (the pump which includes the manifold and Pump <br /> Motor Assembly) is regulated by the Mag-VFC. The IST has a variable speed, three phase motor <br /> which requires three power wires and a ground wire of the proper size and type for installation in <br /> hazardous locations. Grounding the Mag-VFC and the IST is very important and should be done per <br /> the Federal, State, and Local Regulations as well as per the NFPA and NEC. Each IST requires a <br /> Mag-VFC for operation. <br /> Electrical interference is created by several types of equipment in a station (i.e., compressors, <br /> fluorescent lighting, submerged pumps, etc.), some more than others, and this interference can affect <br /> the operation of more sensitive equipment (such as tank monitors and electronic line leak detectors) <br /> which communicate through data lines. Data communication is highly sensitive in some cases and <br /> the routing of equipment power wires (i.e., compressors, fluorescent lighting, IST, etc.) near, or within <br /> the same conduits, raceways, or power panels as communications lines can cause communication <br /> problems. <br /> When installing the Mag-VFC, FE Petro recommends that the power wires from the Power <br /> Source as well as the power wires to the IST be in their own steel conduit which is not broken or <br /> routed through raceways. If this is not possible, at a minimum, power wires need to be in separate <br /> steel conduits from data communication wires. Please see the table below for the maximum wire <br /> length to wire gauge recommendations for submersible wiring. FE Petro also recommends that all <br /> equipment be installed per the manufacturer's requirements for best results. <br /> Wire Size Maximum Run <br /> 10 Gauge 650 Feet <br /> 12 Gauge 400 Feet <br /> 14 Gauge 250 Feet <br /> Please contact Technical Support 'f we may be of any assistance. <br /> Franklin Fueling Systems - 3760 Marsh Rd. • Madison WI 53718 USA <br /> Tel: +1 608 838 8786 • 800 225 9787 • Fax: +1 608 838 6433 •www.franklinfueling.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.