My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
REMOVAL_2010
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
85
>
2300 - Underground Storage Tank Program
>
PR0231656
>
REMOVAL_2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/12/2020 10:43:55 AM
Creation date
5/12/2020 8:55:04 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
REMOVAL
FileName_PostFix
2010
RECORD_ID
PR0231656
PE
2351
FACILITY_ID
FA0003635
FACILITY_NAME
ARCO 06080
STREET_NUMBER
85
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
LATHROP
Zip
95330
APN
19627010
CURRENT_STATUS
01
SITE_LOCATION
85 E LOUISE AVE
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
311
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNIFIED PROGRAM CONSOLIDATED FORM <br /> UNDERGROUND STORAGE TANK <br /> OPERATING PERMIT APPLICATION-TANK INFORMATION t(lnc bili per UST) <br /> f YPF OF ACTION (Check one item onh For an UST permanent closure or removal complete onh this section and Sections I.It.111.IV.and IX below) a'n <br /> ❑ I NEW PERMIT ❑ 3,RENEWAL PERMIT ❑ 5,C'I IANGE OF INFORMA"PION ' <br /> 6 TEMPORARY UST CLOSURE ® 7.UST PERMANENT CLOSURE ON SITE S.UST R EMOVAI. <br /> DATE UST PERMANENTLY CLOSED:12/31/2010 43na DATE EXISTING UST DISCOVERED: <br /> I. FACILITY INFORMATION <br /> FACILITY ID 4(Agency Use On1j) _ _ <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business AS) <br /> ARCO#06080 _ <br /> BUSINESS SITE ADDRESS 101 CITY sill <br /> 85 East LOLISie Avenue Lathrop <br /> 11.TANK DESCRIPTION <br /> TANK ID 4 2 432 TANK MANUFACTURER 41J TANK CONFIGURAI ION- THIS TANK IS 414 <br /> Owens Corning ® I.A STAND-ALONE TANK <br /> ❑2.ONE IN A COMPARTMENTED UNIT <br /> complete one page for each cont artment in die unit <br /> DATE UST SYSTEM INSTALLED 415 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS IN THE UNIT 417 <br /> 1984/10 12 000 1 <br /> III.TANK USE AND CONTENTS <br /> TANK USE ® la.MOTOR VEIIICLLFt1E-LING ❑ Ib.MARINA FUELING ❑ Ic AV)ATION FULLING 439 <br /> ❑ 3.CHEMICAL PRODUCT STORAGE ❑ 4.HAZARDOUS WASTE(includes Used Oil) ❑ 5 EMERGENCY GENERATOR FUEL(HSC§252815(c)] <br /> ❑ 6.OTHER GENERATOR FUEL ❑ 95.UNKNOWN ❑ 99.OTHER (Specify): 439a <br /> CONTENTS PETROLEUM: ❑ 1a REGULAR UNLEADED ® lc MIDGRADE UNLEADED ❑ Ib.PREMIUM UNLEADED 440 <br /> ❑ 3 DIESEL ❑ 5.JET FUEL ❑ 6.AVIATION GAS <br /> ❑ R_PETROLEUM BLEND FUEL ❑ 9.OTHER PETROLEUM (Specify): 440a <br /> NON-PETROLEUM:❑ 7.USED OIL ❑ 10_ETHANOL <br /> ❑ 11 01-IIER NUN-PETROLEUM(Specify) 440b <br /> IV. TANK CONSTRUCTION <br /> TYPE OF TANK ❑ I SINGLE WALL ® 2.DOUBLE WALL 95 UNKNOWN 443 <br /> PRIMARY CONTAINMENT I.STEEL ® 3.FIBERGLASS ❑ 6,INTERNAL BLADDER 444 <br /> ❑ 7 S I'EEL+INTERNAL LINING ❑ 95.UNKNOWN ❑ 99.OTHER ( tf r 444a <br /> SECONDARY CONTAINMENT ❑ 1 STEEL ®3.FIBERGLASS 6.EXTERIOR MEMBRANE LINER ❑ 7 JACKETED 445 <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑99,OTHER(Specify); 4458 <br /> OVERFILL PREVENTION ® I AUDIBLE&VISUAL ALARMS 2 BALI.FLOAT 3 FILL TUBE SHUT-OFF VALVE 452 <br /> ❑ 4 TANK MEETS REQUIREMENTS FOR EXEMPTION FROM OVERFILL.PREVENTION EQUIPMENT <br /> V. PRODUCT/WASTE PIPING CONSTRUCTION <br /> PIPING CONSTRUCTION ❑I.SINGLE-WALLED 0 2,DOUBLE-WALLED 99.OTHER 460 <br /> SYSTEM TYPE ❑ 1 PRESSURE ❑ 2•GRAVITY 3.CONVENTIONAL SUCTION ❑ 4.SAFE SUCTION 2)CCR#26**XJ)j 458 <br /> PRIMARY CONTAINMENT ❑ I STEEL U 4.FIBERGLASS 8.FLEXIBLE 10.RIGID PLASTIC 464 <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑ 99.OTHER( cify): 464a <br /> SECONDARY CONTAINMENT C17 STEEL ❑ 4.FIBERGLASS Q 8.FLEXIBLE ❑ 1-0 RIGID PLASTIC 464b <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑ 99.OTHER( ify) 464c <br /> PIPING(FURBINE CONTAINMENT SUMP TYPE ❑ 1.SINGLE WALL ❑ 2.DOUBLE WALL 90.NONE 464d <br /> VI.VENT,VAPOR RECOVERY(VR)AND RISER/FILL PIPE PIPING CONSTRUCTION <br /> VENT PRIMARY CONTAINMENT LJ L STEEL ❑ 4.FIBERGLASS ❑ 10 RIGID PLASTIC 0 90.NONE L1 99.OTHER(Specify) 464c <br /> 464e1 <br /> VENT SECONDARY CONTAINMENT 0 ].STEEL 0 4.FIBERGLASS D 10 RIGID PLASTIC 0 90.NONE. 99 OTHER(Specify) 464f <br /> 464n <br /> VR PRIMARY CONTAINMENT L STEEL El 4.FIBERGLASS C1 10.RIGID PLASTIC 90 NONE 99 OTHER(Specify) 4648 <br /> 464,1 <br /> VR SECONDARY CONTAINMENT ❑ L STEEL 4.FIBERGLASS 10.RIGID PLASTIC tj 90.NONE El 99 OTHER(Specify) 4646 <br /> 464h1 <br /> VENT PIPING TRANSITION SUMP TYPE 1.SINGLE WALL 2.DOUBLE WALL 90.NONE 4641 <br /> RISER PRIMARY CONTAINMENT Ll 1.STEEL 4 FIBERGLASS ❑ 10 RIGID PLASTIC 0 90 NOM 99 OTHER(Specify) 464j <br /> 464jI <br /> RISER SECONDARY CONTAINMENT ❑ 1.STEEL 0 4,FIBERGLASS Cl 10.RIGID PLASTIC 90.NONE El 99.OTHER(Specify) 464k <br /> 464k1 <br /> FILL COMPONENTS INSTALLED ❑ 1 SPILL BUCKET E3 3 STRIKER PLATEMTTOM PROTECTOR 0 4.CONTAINMENT SUMP 45la-6 <br /> VII.UNDER DISPENSER CONTAINMENT(UDC} <br /> CONSTRUCTION TYPE ❑ I SINGLE WALL ❑ 2.DOUBLE WALL ❑ 3 NO DISPENSERS ❑ 90.NONE 469a <br /> CONSTRUCTION MATERIAL ❑ 1.STEEL ❑ 4.FIBERGLASS ❑ 10 RIGID PLASTIC ❑ 99.OTHER(Specify) 46968 <br /> VI11. CORROSION PROTECTION <br /> STEEL COMPONENT PROTECTION ❑ 2 SACRIFICIAL ANODES) ❑ 4 IMPRESSED CURRENT ❑ 6 ISOLATION 488 <br /> IX. APPLICANT SIGNATURE <br /> CERTIFICATION: I certify that this 1 ST s)s(cmis compatible with the hazardous substance stored and thAt the information provided herein is true,accurate, <br /> and in full compliance with IcRall rcquircmcnls. <br /> APPLICANT SIGNATURE DATE 1 /12/2010 470 <br /> APPLICANT NAMF(print) R C. lossctt 47 APPLICANT TITLE Environmental Compliance Specialist 47' <br /> tIPCF LIST-B-1/2 Rev.(12/2007) <br />