Laserfiche WebLink
PIPING INSTALLATION NOTES: PIPING INSTALLATION NOTES: <br /> INSTALL NEW LOWPOINT, PRODUCT PIPING SUMP, TYPICAL OF ALL CONSTRUCTION IS EXISTING AND TO REMAIN UNLESS <br /> --- 3. CONTRACTOR SHALL DETERMINE INSTALLATION LOCATION NOTED OTHERWISE. <br /> IN FIELD. SEE DETAIIL 1, SHEET TK3-4. <br /> THE CONTRACTOR SHALL MAINTAIN AND PROTECT EXISTING <br /> PL 208+5, / NTE <br /> ST <br /> 19 INSTALL VAPOR RECOVERY, LOWPOINT PIPING SUMP. CANOPY COLUMNS, FOOTINGS AND SHROUD FINISHES IN. <br /> CONTRACTOR SHALL DETERMINE INSTALLATION LOCATION IN PLACE. THE CONTRACTOR SHALL REPAIR OR REPLACE <br /> -- FIELD. SEE DETAIL 2, SHEET TK3-4. CANOPY RAINWATER LEADER IF DAMAGED BY ISLAND <br /> REMOVAL, SEE SHEET CA1-1, TYPICAL. <br /> fo•sf' - PLAt%IER 5 CONTRACTOR SHALL INSTALL NEW HYDROSTATIC MONITOR. <br /> PROVIDE AND INSTALL NEW MANWAY AND TRAFFIC COVER VAPOR AND VENT PIPING IS TO SLOPE AT 1/8" PER FOOT. � <br /> 20 TO GRADE. SIPHON PIPING IS TO SLOPE 1/4" PER FOOT. �, 4) O <br /> C Q , . <br /> 0 <br /> ALL NEW PIPING SHALL BE INSTALLED PER MANUFACTURER'S co(o <br /> -__ RECOMMENDATIONS AND INSTALLATION INSTRUCTIONS. 0� C <br /> CONTRACTOR SHALL USE FLEXIBLE CONNECTORS FROM THE CL U <br /> TANK SUMP TO THE VAPOR RECOVERY MANIFOLD. MAIN 0 <br /> PRODUCT LINES AND SIPHON PIPING SHALL PROVIDE AT <br /> LEAST FOUR (4) FEET OF STRAIT FRP PIPE RUN BEFORE A ,E U •— r <br /> ' ��` , CHANGE OF DIRECTION OF MORE THAN 30 DEGREES. C <br /> 2 O W CL co <br /> " SECONDARY CONTAINMENT PIPING IS SHOWN BY NOTE ONLY, ;r L <br /> ' ' I VI <br /> _ I _ __I» j�-.'L I ' < NOT GRAPHICALLY. ALL PRODUCT PIPE IS TO BE DOUBLE U � I'1 <br /> CONTAINMENT PIPE. VAPOR RECOVERY AND VENT PIPING IS <br /> : :I I . I. :.. . . . .. .. .:�:... a C C ,r-- <br /> 6 7I.: .:I '. C..': TO BE SINGLE WALL PIPE. <br /> . . ' PIPING LEGIEND '♦'' C(E) U.G. VENT PIPING TO REMAIN <br /> `-� <br /> SHALL BE COLORED BLACK CONSULT WITH ARCO FIELD � 0 <br /> 2" F.G. DOUBLE WALL ENGINEER FOR SPECIFICATIONS OF CONCRETE MIX. ALL JANE <br /> cv a �a PRODUCT PIPING <br /> � .. :• ..`I � �: . .I ��I. ..I �L.._ .:•:•:•:..•:•:•:•:.0-;.:. � � CONCRETE SHALL BE NATURAL CALOR COI�LCRETE. 0 W <br /> .: � Y I •:. .'� I.�' I ��I • : .-.'.'.'.'.'.:.:.}:.... � 3' 2" OR 3" F.G. SINGLE <br /> WALL VAPOR RECOVERY <br /> • N � - _ . • � <br /> . . .. J I:' .I �. .: �•' :.�C. ..., , v <br /> CONTRACTOR SHALL <br /> INSTALL NEW 4'x7' CONCRETE <br /> PIPING 4. INSTALL NEW DISPENSER <br /> NS <br /> ER O0 <br /> 2" F.G. DISPENSER ISLAND, Q <br /> sINGLE wALL SPILL CONTAINMENT BOX AT EACH DISPENSER LOCATION <br /> VENT . REFERENi;E SHEET TK3-3 AND TK3 4. <br /> ■ <br /> . •.•. .. ..�....- PIPING TO BE <br /> ."'.,.: :� ' ABANDONED O INSTALL FOUR (4) SCHLUMBERGER "CENTURION" SERIES, r^ <br /> — •—G EXISTING UNDERGROUND MODEL # 33112, 48" FRAME, MULTI-PRODUCT DISPENSERS, W <br /> ::'.... ::'. . 4 UTILITIES (WATER, GAS) TO BE FITTED WITH WITH BALANCE, STAGE I1 HOSES AND """"' <br /> - <br /> 1 1 12 1314 GROSS BUILDING AREA: � �': NEW <br /> ARCO FACILITY 60 CONCRETE CONTAINMENREANCLUDANGJPRODUCT AND ALVES AND DVAPORER SSHEARR <br /> 1 ,843 SQ. FT. NEW A.G. PAVING VALVES AND 3M INTERCOM. SEE DRAWINGS TK3 3 AND <br /> LIJ =�; TK3-4 FOR TYPICAL INSTALLATION DETAILS. SEE DRAWING <br /> C•,•:• cd <br /> TK4-1 FOR DISPENSER WIRING DIAGRAM. START UP BY <br /> TANK ELEVATION:I 0 N: MANUFACTURER'S REPRESENTATIVE. CONTRACTOR TO PURGE <br /> LINES WITH MINIMUM 200 GALLONS PER HOSE. ANY AIR <br /> POCKETS OR START-UP PROBLEMS DUE TO IMPROPER <br /> :�: . . EXISTING. INSTALLATION OR INCORRECT WIRING THAT DESTROYS <br /> ELECTRONICS WILL BE BILLED BACK TO THE CONTRACTOR. <br /> 4 NOTE THAT PIPING TO THE DISPENSERS MUST ALWAYS BE 0 .E <br /> I D : :�._ . „ „ a : <br /> Z �, (E) BUILDING SIDEWALK INSTALLED TO THE B SIDE OF THE DISPENSER TO ENSURE Cd <br /> PROPER MOUNTING TO THE UNDER DISPENSER CONTAINMENT <br /> II � . . . . .. . .> �,„• SUMP: ,.�,- ,,- .,�--� •.� '............... <br /> ,'"_'...,�" , <br /> -�� <br /> Q, 3 INSTALL NEW VEEDER-ROOT DISPENSER SUMP MONITORS, <br /> Ci <br /> 4. '� c�i TYPICAL OF 4. <br /> C Y1 <br /> 1 A .-- 1 6 -' � li ® CONTRACTOR "5WALL'tNS tACL-NE GLE MALL, <br /> - -- FIBERGLASS VAPOR RECOVERY PIPING FOR "BALANCE" C <br /> C. n- VAPOR RECOVERY SYSTEM, SLOPE 1/8" PER FOOT TO TANK, <br /> : : . . <br /> .. . ,. .... __ Y�� 4 SEE DETAILS AND S - <br /> (E) ATM TOO CONTRACTOR SHALL INSTALL NEW 2", DOUBLE WALL, <br /> 2 PIPING <br /> �_. <br /> _ FIBERGLASS, PRODUCT PIPING SLOPE 1/8" PER FOOT TO <br /> TI TANKS, SEE DETAIL 10, SHEET TK3- FOR TYPICAL <br /> . . . . .' . .. .. i ARRANGEMENT. LINES TO BE EQUIPPED WITH LEAK MONITOR <br /> Cd <br /> IN PIPING SUMP, ATTACHED TO TANK LEAK MONITOR AND <br /> o 1 r)OWN ,`P111 HALL BE �. <br /> s uenr_n rn� Tt tot�Iwlr CL�i 'T [(` r <br /> .. - . - .... <br /> . � = -1- INSTALLED PER MANUFAC'TURER'S RECOMML' . ATIONS.. <br /> 92-. :. <br /> . � .� ® CONTRACTOR SHALL PA-fCH AND/OR REPAIR EXISTING <br /> ( �� CONCRETE SLAB OVER TANKS. SET MANHOLE COVERS <br /> 1-1/2 ABOVE SLAB. SEE DETAILS, SHEET TK3-5. MAINTAIN Lo} <br /> 2% MAXIMUM SLOPE ACROSS TANK SLAB. <br /> W <br /> CONTRACTOR SHALL PA'T'CH AND/OR REPAIR EXISTING A.G. � Q <br /> . . . . . PAVING AND CONCRETE AS REQUIRED BY NEW WORK. <br /> - ® CONTRACTOR SHALL INSTALL NEW SINGLE WALL, FIBERGLASS <br /> . . . . x. . TANK VENT PIPING. CONNECT TO EXISTING PIPING, SLOPE W <br /> — — — BACK TO TANK AT 1 8" PER FOOT, TYPICAL OF THREE <br /> --�- . <br /> . . . . . . . . . . .: : . . . ::: ,a TANKS. / I-' <br /> Z <br /> .. . ..: :::...:. 90 CONTRACTOR SHALL INS-TALL NEW HORSESHOE BUMPER Q "— <br /> ...... . . .. . . .. <br /> POST, TYPICAL OF 2. SEE DETAIL 16, DRAWING TK3-4. <br /> a <br /> .o CJ CL <br /> 5' 15 5' 10 CONTRACTOR SHALL INSTALL NEW VEEDER-ROOT TLS-350 > W o <br /> .o �� 2 3 CONNECTkONTANK O5R VERIFY UNIT LOUNIT AND �AITION WITATED OH�ARCODFIELDSOR C Q <br /> 22' ENGINER. w W <br /> .sem <br /> 46 1 INSTALL ONE (1) 2 H.P. VARIABLE SPEED TURBINE 1N EACH, � --- 0 <br /> 12,000 GALLON, TANK TURBINE SUMP <br /> 12 Jf ~Ew...DRAWING.,-TK4-„..FOR ,,MONITORING CQNDUIT,1)€•T'A L-`AN b / F�''� J �, LJJ � <br /> SENSOR AND PROgE MOUNTING DETAILS. ��� LC) a a <br /> UNAUTHORIZED CHANGES AND USES: The engineer pre ring t e PLANTER 00 J O <br /> laps will not be responsible for, or liable for unauthor d 13 INSTALL NEW 48” DIA TURBINE SUMP. INSTALL NEW TURBINE <br /> p SUMP COLLAR AS REQUIRED BY TANK MANUFACTURER <br /> changes to or uses of these pians. All changes plans t b <br /> In writing and must be approved by the preparer of these a / PLANTER (SUBCONTRACTOR TO G,.C.) TYPICAL OF 3. <br /> BACKFILL AND COMPACT TANK EXCAVATION IN ACCORDANCE <br /> Construction contractor agrees that in accordance with generally — — — — � — � <br /> accepted construction practices, construction contractor will be WITH ARCO SPECIFICATIONS. PATCH AND/OR REPAIR A.C. <br /> required to assume sole and complete responsibility for job site PL = 203.0 PAVING TO MATCH EXIS fiNG.. <br /> conditions during the course of construction of this project, <br /> including safety of all persons and property, that this requirement 15 CONTRACTOR SMALL MC'DlFY EXISTING CANOPY COLUMN <br /> in g Y SHROUD AND EXTEND TO GRADE. EXTEND CANOPY DOWN o as <br /> shall be made to apply continuously and not limited to normal <br /> working hours, and construction contractor further agrees to SPOUT DRAIN LINE TO FACE OF SHROUD, TYPICAL OF 3. Z - vi X <br /> and hold design professional harmless from any <br /> indemnify 9 P 16 CONTRACTOR SHALL PROVIDE AND INSTALL NEW, WALL LO U <br /> defend, Inde y O <br /> and all liability, real or alleged, In connection with the performance <br /> of work on this project, excepting liability arising from sole MOUNTED, EMERGENCY 'SHUT-OFF SWITCH, WITH PROTECTIVE a °A ° 4 S W <br /> UW >o -,t <br /> COVER AND SIGNAGE. INSTALL AT 42" ABOVE SIDEWALK C� 0 C C i <br /> negligence of design professional. SURFACE. COMPETE ALL, CONNECTIONS TO EXISTING W 0 Inc) n <br /> - ZLECTRIGAI,.S` 5T.Eful_ ANQ,-RAN,E�.--VERIFY- LOCATION WITH ¢ -� a Co " <br /> Note o Co t 2 ,ARCO FIELD ENGINEER. y� r � a o a�0°a o <br /> The existence and location of any underground utilities, pipes, <br /> Q M ay <br /> and/or structures shown on 'these plans were obtained by a 17 ***NOT USED*** el `� <br /> ***NOT USED*** master release date <br /> search of available records. To the best of our knowledge, there <br /> are no existing utilities except as shown on these plans. The /gi /+A c <br /> contractor shall ascertain the true vertical and horizontal location GRAPHIC �SCALG <br /> and size of those to be used of any underground utilities and <br /> shall be responsible for any damage to any public or private 10 5 1 N DATE REVISIONS � PROJECT RELEASE proj. exe. drawn by <br /> 1 _ 7/30/99 REV PER CLIENT COMMENTS <br /> utilities, shown or not Shawn hereon. DE3G/CSD <br /> PERMIT _ <br /> IMPORTANT NOTICE inch 1(0 feet <br /> IN FEET) 2 9/01/99 REV. PER CLIENT COMMENTS project / facility <br /> Section 4216/4217 of the Government Code requires <br /> HID 60810 <br /> a Di Alert Identification Number be issued before a <br /> Permit to Excavate will be valid. For your Dig Alert <br /> Isheet / file <br /> D Number Call <br /> CONST. <br /> UNDERGROUND SERVICE ALERT TK - 1 <br /> 1 -800-227-2600 <br /> AS-BUILT <br /> of <br /> For Underground Locating, 2 working days before you dig. <br /> AR995/995/995C1-1,DWG <br />