Laserfiche WebLink
5.3 LOCATION OF UNDERGROUND UTILITIES <br />' <br /> -2L-USA Private Locator Plans Check X_Property Owner <br />' 5.4 OVERHEAD POWER LINES <br /> Whenever possible, avoid working under overhead high voltage lines If overhead power lines are <br /> present on the site, the following are muumum clearances to be maintained between overhead high <br /> 1 voltage lutes and personnel and equipment <br />' Nominal Voltage Minimum Required <br /> (phase to phase) Clearance (feet) <br /> 750- 50,000 10 <br /> 50,000- 75,000 11 <br />' <br /> 75,000- 125,000 13 <br /> 125,000- 175,000 15 <br /> 175,000- 250,000 17 <br /> 250,000- 350,000 21 <br /> 370,000- 550,000 27 <br /> 5501000- 1,000,000 42 <br /> (Based on CCR Title 8, Section 2946) <br />' 5.5 NOISE HAZARDS <br /> Use hearing protection any time sound levels exceed 85 dba <br /> 5.6 HEAT STRESS HAZARDS <br /> Significant during summer months Avoid heat stress by dnnking liquids frequently Remove <br />' affected personnel from area <br />' 4 <br />