Laserfiche WebLink
5.3 LOCATION OF UNDERGROUND UTILITIES <br /> i <br /> USA Private Locator _Plans Check X Property Owner <br /> 5.4 OVERHEAD POWER LINES <br /> Whenever possible, avoid working under overhead high voltage lines. If overhead power lines are <br /> present on the site, the following are minimum clearances to be maintained between overhead high <br /> Lvoltage lines and personnel and equipment: <br /> (Nominal Voltage Minimum Required <br /> (phase to phase) Clearance (feet) <br /> L750- 50,000 10 <br /> 50,000- 75,000 11' <br /> 75,000- 125,000 13 <br /> L <br /> 125,000- 175,000 15 <br /> 175,000- 250,000 17 <br /> 250,000- 350,000 21 <br /> 370,000- 550,000 27 <br /> 550,000- 1,000 000 42 <br /> (Based on CCR Title 8,Section 2946.) <br /> I <br /> 5.5 NOISE HAZARDS <br /> Use hearing protection any time sound levels exceed 85 dba. <br /> L ; <br /> 5.6 HEAT STRESS HAZARDS <br /> II <br /> Significant during summer months. Avoid heat stress by drinking liquids frequently. Remove <br /> Laffected personnel from area. <br /> L 1 ' <br /> Ij <br /> 4 i <br /> I! <br /> i <br />