My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1711
>
2300 - Underground Storage Tank Program
>
PR0231455
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/3/2020 12:26:00 PM
Creation date
5/13/2020 11:38:28 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231455
PE
2361
FACILITY_ID
FA0003612
FACILITY_NAME
Yosemite Avenue Arco AmPm
STREET_NUMBER
1711
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
Ave
City
Manteca
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
1711 E Yosemite Ave
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
62
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
f <br /> UNDERGROUND STORAGE TANK <br /> MONITORING SYSTEM CERTIFICATION FORM (Page 1 of 6 <br /> FTh1sform must be used to document testing and servicing of underground storage tank (UST) monitoring equipment. A copy of this form <br /> be provided to the UST owner or operator. The owner or operator must submit a copy of this form to the local agency regulating the <br /> within 30 days of the date of the monitoring system certification. <br /> 1 . FACILITY INFORMATION <br /> CERS ID Date of Monitoring System Certification <br /> 10422475 16/14/2019 <br /> Business Name (Same as Facility Neme or DSA — Bing Business As.) Building # <br /> Yosemite Avenue Arco Am Pm <br /> Business Site Address City ZIP Code <br /> 1711 E . Yosemite Ave . I Manteca 195336 <br /> IL UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of Company Performing the Certification Phone # <br /> Diamond Petroleum Services , inc. (925) 470 - 0803 Ext, <br /> Mailing Address <br /> 3619 King Ct. Antioch , CA 94509 <br /> Name of UST Service Technician Performing the Certification (Pdntas shown on the ICC Certification.) <br /> Guadalupe Sanchez <br /> Contractor/Tank Tester License # ICC Certification # ICC Certification Expiration Date <br /> 1005444 5250451 4/5/2021 <br /> Monitorina System Trainin and Certifications Ust all applicable cel ficallons. Expiration Date <br /> Veeder Root A30138 10/30/2019 <br /> VMI Va orless LDT-890 Tester # 4068 6/13/2021 <br /> VMI Mechanical Leak Detector Installer # 4067 6/13/2021 <br /> III. RESULTS OF TESTING/SERVICING <br /> Indicate and attach the following reports if the monitoring equipment Is capable of generating either. Y N NA <br /> ® Monitoring System Set-up ® Alarm History Report <br /> Was any monitoring equipment replaced? 10 E3 0 <br /> (if 'Yes, " identify the specific devices replaced and list the manufacturer and model for all replacement parts in section W below.) <br /> Was damage, debris, or liquid found inside any secondary containment systems? ® 11 ❑ <br /> (if Wes, " describe what was found in section IV below.) <br /> Is all monitoring equipment operational per manufacturer's specifications? <br /> (If "No, " describe why in section IV below.) <br /> N. COMMENTS <br /> If directed to use this section, describe how and when the issues were or will be corrected. <br /> The 87 PLLD was replaced "like for like" model 8484 in the 87 Master tank. <br /> Water was found in all fill sumps. <br /> Water was removed and placed into a 55 gal HAZ drum located on site. <br /> The 91 annular sensor failed to activate an audible and visual alarm when tested . <br /> The 91 annular sensor needs to be replaced <br /> H <br /> V. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS TESTING <br /> I hereby certify that the equipment identified in this document was inspected/serviced in accordance with California Code of <br /> Regulations, title 23, division 3, chapter 16, section 2638 and all information contained herein is true and accurate. Attached to <br /> this certification is information (e.g., manufacturers' checklists, monitoring system set-up, alarm history report, etc.) necessary <br /> to verify that this information and the site plan showing the layout of UST system is complete and accurate. <br /> UST Service Technician Signature <br /> r FRR f aiNnmia FrndrrvunwMal Rnnnrfinn CvaMm IT1 a kfoMiRraHnn rfY Intwmafirva! f rx#a f ry �nr9 Y c Yc¢ N a Nn NA = Not anrAhmtda <br />