My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1711
>
2300 - Underground Storage Tank Program
>
PR0231455
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/15/2020 9:49:52 AM
Creation date
5/13/2020 11:55:16 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231455
PE
2361
FACILITY_ID
FA0003612
FACILITY_NAME
Yosemite Avenue Arco AmPm
STREET_NUMBER
1711
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
Ave
City
Manteca
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
1711 E Yosemite Ave
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
53
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Afford- a -test <br /> Secondary Containment/SB989 - a (20Rr j4-0112 <br /> Line/Leak Detectors i <br /> Tank Monitor Certification <br /> Air Quality Testing <br /> Overfill Prevention/Drop Tube Testing APR <br /> California UST Service Technicians <br /> California UST SWRCB Tank Testing <br /> ated License Oerators ��VIVI � . �,MU� g ' L f` L , (21 Lrc , l <br /> CSLB License #341375 t = E t ; N # . <br /> Secondary Containment Test Procedure Used To Determine Test Results <br /> Tank Secondary Containment — The Service Technician will test and certify using <br /> methods developed and recommended by the Tank Manufacture, Industry Standard or <br /> Professional Engineer . Test procedure recommended and used is a vacuum slowly <br /> applied to establish a stable vacuum of 6" to 10 " inches Hg . for one hour using a <br /> Standard Industry Vacuum Gauge with a range of 4 ' to -30 " measured in Hg . /inches of <br /> mercury . The test is completed at the end of one hour/Tanks with a Volume of 20 , 000 <br /> Gallons or less, and 2 hours for Tanks that exceed a Volume of 20 , 000 Gallons , if the <br /> vacuum reading does not decrease below the established vacuum or the Threshold <br /> Criteria recommended by the Tank Manufacture , Industry Standard, or Professional <br /> Engineer . <br /> Product Piping Containment/Vent Piping Containment/Vapor Recovery Piping <br /> Containment — The Service Technician will test and certify using methods developed <br /> and recommended by the Piping Manufacture , Bravo System UDC Manufacture, Industry <br /> Standard or Professional Engineer . Test procedure recommended and used is , Nitrogen <br /> Gas pressure , slowly applied to establish a stable pressure of 5 psi for one hour or 3 Psi <br /> for 1 hour using a Standard Industry Pressure Gauge with a range of 0 to 15 measured in <br /> Psi/Pounds per square inch . If the Product Piping is Fiberglass and the UDC ' s are a <br /> j Bravo System Manufacture, constructed of Coated Steel , with an O Ring Seal at <br /> Primary/Secondary Product Piping Interface at end of Product Piping Run at UDC ' s then, <br /> Bravo System Manufacture recommends a maximum applied test pressure of 3 Psi . The <br /> test is completed at the end of one hour if the pressure reading does not decrease below <br /> the established pressure or the Threshold Criteria recommended by the Piping <br /> Manufacture, Bravo System UDC Manufacture, Industry Standard or Professional <br /> Engineer. <br /> r <br /> Turbine/Product Piping Sump/Fill Riser Sump/Remote Fill Sump/Transition/Vent <br /> Sump/Spill Container/Misc. Sump connected to UST System — The Service <br /> Technician will test and certify using methods developed and recommended by the Sump <br /> Manufacture, Industry Standard or Professional Engineer. The test procedure <br /> recommended and used is Hydrostatic with a level change indicator that has been <br /> developed to indicate a standard leak rate of 1/4 inch in 24 hours within 30 minutes , and <br />
The URL can be used to link to this page
Your browser does not support the video tag.