Laserfiche WebLink
TABLE C-1 <br /> SUMMARY OF QUALIFIED DATA <br /> Alden Park <br /> Tracy, California <br /> SDG/ <br /> Lancaster Result Reason <br /> Field Sample ID Report Number Lab Sample ID Sample Purpose Matrix Parameter (%or pg/L) MDL LOQ Qualifier Code Reason for Qualification <br /> MW-7-W-090116 1128950 5581542 Field Sample Water TPHd 280 50 E V05 Professional judgment was used to qualify the data <br /> TPHd 54 50 E V05 Professional judgment was used to qualify the data <br /> Naphthalene ND 0.05 E A01 Extraction holding times were exceeded <br /> Acenaphthylene ND 0.01 E A01Extraction holding tunes were exceeded <br /> Acenaphthene ND 0.01 E A01 Extraction holding times were exceeded <br /> Fluorene ND 0.01 E AOI Extraction holding times were exceeded <br /> Phenanthrene ND 0.01 E A01 Extraction holding times were exceeded <br /> I Anthracene ND 0.01 - A01 -Extraction holding times _.. __. <br /> _ es were exceeded <br /> Fluoranthene ND 0.01 E A01Extraction holding times were exceeded <br /> Phyrene 0.022 0.01 E A01Extraction holding times were exceeded 1 <br /> MW-9-W-090116 1128950 5581543 Field Sample Water <br /> Benzo(a)anthracene N-D 0.01 E _ A01 Extraction holding times were exceeded <br /> Chrysene ND 0.01 E A01 Extraction holding times were exceeded <br /> Benzo(b)Fluoranthene ND 0.01 E A01 Extraction holding times were exceeded <br /> IBenzo(k)Fluoranthene ND 0.01 E AOI Extraction holding times were exceeded <br /> Benzo(a)pyrene ND 0.003 E A01 Extraction holding times were exceeded <br /> Indeno(1,2,3 cd)pyrene ND 0.01 E A01 Extraction holding times were exceeded <br /> _ _... <br /> Dibenz(a,h)anthracene ND 0.003 E A01 Extraction holding times were exceeded <br /> Benzo(g,h,i)peryIene ND 0.01 E A01 Extraction holding times were exceeded <br /> Pryrene 0.022 0.01 E POI LCS recovery was above upper control limit <br /> Benzo(a)anthracene 0.011 0.01 E F01 Sample data were qualified as a result of the method blank <br /> Chry.sene 0.011 0.01 E F01 Sample data were qualified as a result of the method blank <br /> Benzo(b)Fluoranthene 0.017 0.01 E F01 Sample data were qualified as a result of the method blank <br /> MW-8-W-090115 1128527 5579114 Field Sample Water Benzo(k)Fluoranthene 0.016 0.01 E F01 Sample data were qualified as a result of the method blank <br /> Benzo(a)pyrene 0.011 0.003 E F01 Sample data were qualified as a result of the method blank <br /> lndeno(1,2,3-cd)pyrene 0.016 0.01 E F01 Sample data were qualified as a result of the method blank <br /> Dibenz(a h)anthracene 0.016 0.003 E F01 Sample data were qualified as a result of the method blank <br /> Be.nzo(g,h,i)perylene 0.016 0.01 E FO Sample data were qualified as a result of the method blank <br /> Abbreviations: <br /> E—Indicates the reported value is estimated due to associated quality control results <br /> 3=Indicates the reported value is an estimated concentration detected between the MDL and LOQ <br /> j TPHd=Total petroleum hydrocarbons quantified as diesel,carbon range Cl,)-C25 <br /> LOQ=Limit of quantitation <br /> MDL=Method detection limit <br /> mg/kg=Milligrams per kilogram <br /> SDG=Sample delivery group <br /> Vg/L=Micrograms per liter <br /> Frain 5cienra to Sulu[iaf3� <br /> I Page 1 of I <br />