My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_ANNUAL 2010 GROUNDWATER MONITORING AND SAMPLING REPORT
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SEQUOIA
>
500
>
2900 - Site Mitigation Program
>
PR0505768
>
ARCHIVED REPORTS_ANNUAL 2010 GROUNDWATER MONITORING AND SAMPLING REPORT
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/13/2020 2:36:11 PM
Creation date
5/13/2020 2:16:56 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
ANNUAL 2010 GROUNDWATER MONITORING AND SAMPLING REPORT
RECORD_ID
PR0505768
PE
2960
FACILITY_ID
FA0006988
FACILITY_NAME
ALDEN PARK CHEVRON
STREET_NUMBER
500
Direction
N
STREET_NAME
SEQUOIA
STREET_TYPE
AVE
City
TRACY
Zip
95376
APN
23416001
CURRENT_STATUS
01
SITE_LOCATION
500 N SEQUOIA AVE
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
97
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' Mr.Lee Higgins-CEMC <br /> Annual 2010 Groundwater Monitoring and Sampling Report April 19,2010 <br /> Alden Park Page 4 of 7 <br /> ' <br /> Depth to groundwater was measure <br /> p g d in MW-4, MW-7 through MW-12, and MW-14 on <br /> January 5, 2010. Cumulative depth-to-groundwater measurements and groundwater <br /> ' elevations are provided in Table 1. A potentiometric map showing groundwater <br /> elevation contours and flow direction is shown on Figure 3. Field data sheets are <br /> ' provided as Attachment B. <br /> • Site Wells in Program: MW-1, MW-3 through MW-12, MW-14 through <br /> MW-16, MW-18, MW-20, and MW-21. <br /> ' • Wells Containing SPO: MW-1, MW-3, MW-5, MW-6, MW-15, MW-16, MW- <br /> 18, MW-20, and MW-21 have historically contained SPO. MW-5 and MW-21 <br /> ' contain oil-absorbent(oleophilic) socks that are monitored on a semi-annual <br /> basis. Vacuum extraction of SPO from the remaining wells is performed on a <br /> quarterly basis. <br /> ' • Depth to Groundwater at the Site: Ranged from 11.42 feet below top of casing <br /> (btoc) in MW-8 to 14.18 feet btoc in MW-11. Depth-to-groundwater <br /> measurements collected to date from these wells indicate that the average depth to <br /> ' groundwater at the site is 11.23 feet btoc. <br /> • Calculated Groundwater Elevation: Ranged from 38.36 feet above mean sea <br /> ' level (MSL) in MW-7 to 41.33 feet above MSL in MW-12. Groundwater <br /> elevation measurements collected to date from these wells indicate that the <br /> average groundwater elevation at the site is 41.54 feet above MSL. <br /> ' • Approximate Groundwater Flow Direction/Gradient: Predominantly toward <br /> the north northwest at 0.003 ft/ft, which is consistent with historic groundwater <br /> flow-gradient site data. <br /> ' SAMPLING <br /> MW-4, MW-7, MW-8, MW-10, MW-11, and MW-12 were purged by the regulatory- <br /> approved, low-flow minimal drawdown method using a low-flow submersible pump with <br /> dedicated polyethylene tubing following depth-to-groundwater measurements. MW-9 <br /> and MW-14 were purged using the three-volume purge method because draw down <br /> ' exceeded 0.33 foot. Measurements of pH, specific conductance, temperature, oxygen- <br /> reduction potential, turbidity, and dissolved oxygen water-quality parameters were <br /> ' recorded during the purge process. Groundwater samples were collected after water- <br /> quality parameters stabilized (stabilization criteria are shown on the field data sheets). <br /> The groundwater samples were decanted into laboratory-provided bottles, which were <br /> I ' labeled, sealed, and placed immediately into an ice-cooled container for delivery to <br /> Lancaster Laboratories, Inc. (Lancaster)3, under SAIC chain-of-custody protocol. <br /> Samples were not collected from MW-1, MW-3, MW-5, MW-6, MW-15, MW-16, <br /> ' MW-18, and MW-20 due to the presence of SPO. A sample was not collected from <br /> MW-21 due to the presence of sheen. <br /> ' 3. Lancaster is a California-certified laboratory(FLAP#2116). <br />
The URL can be used to link to this page