My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FRENCH CAMP
>
17641
>
1900 - Hazardous Materials Program
>
PR0535938
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/13/2020 2:57:23 PM
Creation date
5/13/2020 2:40:36 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1900 - Hazardous Materials Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0535938
PE
1921
FACILITY_ID
FA0020697
FACILITY_NAME
TURKHAN FOODS INC
STREET_NUMBER
17641
STREET_NAME
FRENCH CAMP
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
20322021
CURRENT_STATUS
01
SITE_LOCATION
17641 FRENCH CAMP RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J O A Q U I N Environmental Health Department <br /> COUNTY <br /> Hazardous Materials Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> TURKHAN FOODS INC 1 17641 FRENCH CAMP RD, RIPON August 14, 2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 5 HSC 25506(a)(1) Failed to complete and/or submit hazardous materials inventory for all reportable materials on site. <br /> 280 gallons of diesel in the fire pump house were found on site that have not been reported. Any material that <br /> meets or exceeds the reportable quantity shall be reported in the facility's business plan.The max daily amounts for <br /> propane is not correct.The max daily amount is being reported as 100 gallons but there 2,499 gallons of propane <br /> on site at time of inspection. Immediately log into the California Environmental Reporting System (CERS)at <br /> http://cers.calepa.ca.gov/,add the materials to the hazardous material inventory, and submit to the EHD for <br /> approval. <br /> This is a minor violation. <br /> 6 HSC 25505(a)(2) Failed to complete and/or submit a site map with all required content. <br /> A site map was not completed or submitted as part of the business plan.The site map is missing adjacent streets <br /> locations, and emergency shut off locations for the propane. A site map shall contain a north orientation, loading <br /> areas, internal roads,adjacent streets,storm and sewer drains,access and exit points, emergency shutoffs, <br /> evacuation staging areas, hazardous material handling and storage areas, and emergency response equipment. If <br /> a site map element is not applicable for your facility then list it on the map and label as"NA". Immediately log into <br /> the California Environmental Reporting System (CERS)at http://cers.calepa.ca.gov/, upload the correct or updated <br /> information,and submit to the EHD for approval. <br /> This is a minor violation. <br /> 7 HSC 25505(a)(3) Failed to establish and/or submit emergency response procedures for a release or threatened <br /> release. <br /> The emergency response procedures are not complete. Please put the local Certified Unified Program Agency <br /> (CUPA)phone number as 209-468-3420. Please put the date in for section A2. A business plan shall include the <br /> following emergency response procedures for a release or threatened release of hazardous materials, including, but <br /> not limited to,the following: <br /> -immediate notification of local emergency personnel and the Environmental Health Department(EHD) <br /> -procedures for the mitigation of a release or threatened release to minimize any potential harm or damage to <br /> persons, property, or the environment <br /> -evacuation plans and procedures, including immediate notice,for the site <br /> Immediately log into the California Environmental Reporting System(CERS)at http://cers.calepa.ca.gov/, upload the <br /> correct or updated information,and submit to the EHD for approval. <br /> This is a Class II violation. <br /> 9 HSC 25508(a)(1) Failed to annually review and certify that the business plan is complete, accurate, and up to date. <br /> The business plan information has not been reviewed and resubmitted in the California Environmental Reporting <br /> System(CERS)annually.The last submittal made was 5/22/2017. Please make a submittal for 2018 The <br /> hazardous materials inventory shall be submitted by January 15 of each calendar year and may be submitted <br /> beginning November 1 of the previous year. Immediately log into the CERS at http://cers.calepa.ca.gov/, enter the <br /> correct or updated information, and submit to the EHD for approval. <br /> This is a Class II violation. <br /> FA0020697 PR0535938 SCO01 08/14/2018 <br /> EHD 19-01 Rev.10/31/2017 Page 2 of 3 Hazardous Materials Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.