TRAFFIC RATED WELL COVER <br /> **Note:3 FEET OF 1/4"TEFLON TUBING WILL BE <br /> ABOVE GROUND SURFACE(Not illustrated) <br /> SURFACE GRADE <br /> 1/4"TEFLON TUBING <br /> 3 FEET asg(above surface grade)-5 1/2 FEET bsg <br /> NEAT CEMENT SEAL(BENTONITE 1-5%), 1/2-4 1/2 FEET bsg <br /> DRY BENTONITE CHIP SEAL,4 1/2-5 FEET bsg <br /> t <br /> VAPOR PROBE FILTER PACK(#2/12 SAND)5-6 1/2 FEET bsg <br /> 5 1/2-6 FEET bsg <br /> 4"BOREHOLE DIAMETER <br /> ALL DEPTHS RELATIVE TO SURFACE GRADE <br /> NOT TO SCALE <br /> PROPOSED SOIL-VAPOR WELL Advanced <br /> NOMELLINI CONSTRUCTION COMPANYGeoEnvironmental, Inc. <br /> qm www.advgeoenv.com <br /> 1045 WEST CHARTER WAY PROJECT NO. AGE-95-0141 FILE: SVWELL FIGURE <br /> STOCKTON, CALIFORNIA DATE: DECEMBER 2016 DRAWN BY MAC 5 <br />