20 October 1999 <br /> AGE-NC Project No. 99-0645 <br /> Page 5 of 5 <br /> 4.I. SOIL EXCAVATION PROCEDURES <br /> Soil will be excavated using an excavator. Soil will be placed into an end-dump truck for <br /> transportation to Forward Landfill. Excavated soil will be field screened for the presence of volatile <br /> organic compounds using an OVM. Based on OVM readings and field observations, excavated soil <br /> will be segregated into clean soil (if appropriate)and impacted soil; only soil exhibiting hydrocarbon <br /> odors or measured OVM readings will be transported for disposal. The excavation will be backfilled <br /> withcan fi material or pea gravel. <br /> The open excavation area will be surrounded by temporary fencing. No AGE or subcontractor <br /> personnel will be allowed into any excavation greater than five feet bsg without proper excavation <br /> shoring and/or sloping techniques are in-practice and supervised. <br /> 4.2. SOIL SAMPLING PROCEDURES <br /> Soil samples collected from the base and sidewalls of the excavation will be obtained using a <br /> backhoe or excavator. Soil samples will be collected from the bucket of the excavating equipment <br /> with a metric soil sampling hammer and one 6-inch long by 2-inch diameter brass sleeve, from the <br /> excavated soil material. The exposed ends of the sample sleeve will be covered with Teflon sheets, <br /> capped and sealed with tape. <br /> Soil samples will be collected from soil stockpiles by digging approximately one foot into the soil <br /> stockpile. Soil samples will be collected by hand sampling methods using a stainless steel or carbon <br /> steel trowel, by pressing a metric soil sampling hammer and one 6-inch long by 2-inch diameter <br /> brass sleeve into the soil stockpile. <br /> Following sample collection, each sample sleeve will be labeled with the boring location, depth, <br /> time, date and sampler's initials. Appropriately sealed and labeled samples will be placed in a chilled <br /> container under ice and transported under chain-of-custody procedure to a DHS-certified laboratory. <br /> 4.3. EQUIPMENT DECONTAMINATION <br /> Prior to each sample collection, all sampling tools used for sample collection will be thoroughly <br /> rinsed with clean water after being washed with a solution of Alconox. <br /> Advanced CeoEnvirunmenul.Inc. <br />